Fisher Aircon Solutions FSL-124HF Technical & Service Manual Download Page 32

FSL244HF   Indoor unit 

 

No. 

Part  Name 

Quantity

No. 

Part  Name 

Quantity

1 Cover 

24 Left 

cover 

board 

Rear-right clapboard 

25 

Electric control ass’y 

Front-right clapboard 

25.1 

Electric part box 

4 Evaporator 

25.2 Main 

control 

board 

Guiding board for water draining 

25.3 

Transformer 

Middle beam 

25.4 

Wire joint, 7p 

Right cover board 

25.5 

Wire joint, 2p 

Water collector   

26 

E-box support board I 

Capacity 

27 

E-box support board II 

10 

Capacitor box 

28 

Holder for remote controller 

11 Axis 

29  Remote 

controller 

12 

Bearing 

30 

E-Parts box cover 

13 

Bearing seat 

31 

Pipe supporting board 

14 

Fan ass’y 

32 

Pipe clamp board 

15 

Air inlet channel 

33 

Input pipe 

16 Air 

filter 

34  Output 

pipe 

17 

Right fixing clamp for motor 

35 

Rear-left clapboard 

18 

Left fixing clamp for motor 

36 

Front-left clapboard 

19 

Holder for fan motor 

37 

Evaporator temp sensor 

20 

Fan motor 

38 

Installing board for display box 

21 

coupling 

39 

Cover for display board 

22 

Strengthen board for motor 

40 

Display board 

23 

Evaporator temp sensor 

41 

Display box 

 

- 31 -

Summary of Contents for FSL-124HF

Page 1: ...TECHNICAL SERVICE MANUAL DUCT SLIM TYPE AIR CONDITIONER FSL 124HF FSL 184HF FSL 244HF FI SM 040823...

Page 2: ...Table 9 Part 6 Outlines and Dimension 12 Part 7 Electric Control Functions 15 Part 8 Wiring Diagram 24 Part 9 Installation 24 Part 10 Servicing and Maintenance 27 Part 11 Exploded view 29 NOTICE Spec...

Page 3: ...Part 1 Product Features Quietest operation low noise Thin design space saving Easy to operate remote control 2...

Page 4: ...Supplier TOSHIBA GUANG DONG Capacity Btu h 14600 14800 Input W 1400 1430 Rated current RLA A 6 5 Locked rotor Amp LRA A 7 5 Thermal protector UP3RE0591 T56 Capacitor uF 35 Compressor Refrigerant oil m...

Page 5: ...Packing W H D mm 890 655 355 Outdoor unit Net Gross weight Kg 40 45 Refrigerant type R407C g 1330 Design pressure MPa 1 2 3 5 Liquid side Gas side mm inch 6 35 12 7 1 4 1 2 Max refrigerant pipe lengt...

Page 6: ...OREA Capacity Btu h 20130 20267 29000 Input W 1980 2105 2760 Rated current RLA A 9 7 10 3 12 4 Locked rotor Amp LRA A 50 61 Thermal protector INTERNAL TYPE INTERNAL TYPE Capacitor uF 40 60 Compressor...

Page 7: ...48 52 Dimension W H D mm 845X695X335 895X860X330 Packing W H D mm 965X847X395 972X987X406 Outdoor unit Net Gross weight kg 55 58 79 90 Refrigerant type g R407C 2050 R407C 2500 Design pressure MPa 1 2...

Page 8: ...igh airflow FSL 124HF FSL 184HF Octave band center frequency Hz Sound pressure level dB 0dB 0 0002 bar Audibility limits of continuous white sound FSL 244HF Octave band center frequency Hz Sound press...

Page 9: ...Part 4 Operation Range Ensure the operating temperature is in allowable range 8...

Page 10: ...4 89 4 68 4 51 4 26 4 08 3 96 3 83 Sensitive capacity kW 3 91 3 74 3 61 3 40 3 27 3 17 3 06 32 C D 23 C W Input kW 1 13 1 29 1 45 1 61 1 77 1 93 2 09 Model FSL 124HF HEATING OUTDOOR TEMPERATURE Indoor...

Page 11: ...6 10 5 85 5 67 5 49 Sensitive capacity kW 5 61 5 36 5 17 4 88 4 68 4 53 4 39 32 C D 23 C W Input kW 1 77 2 02 2 28 2 53 2 78 3 04 3 29 Model FSL 184HF HEATING OUTDOOR TEMPERATURE Indoor Conditions 24...

Page 12: ...8 28 7 95 7 70 7 45 Sensitive capacity kW 7 62 7 29 7 02 6 62 6 36 6 16 5 96 32 C D 23 C W Input kW 2 50 2 85 3 21 3 57 3 92 4 28 4 63 Model FSL 244HF HEATING OUTDOOR TEMPERATURE Indoor Conditions 24...

Page 13: ...Part 6 Outlines and Dimension 7 1 Indoor unit FSL 124HF FSL 184HF 12...

Page 14: ...FSL 244HF 7 2 Outdoor unit FSO 124HF 13...

Page 15: ...FSO 184HF 12 5 FSO 244HF A BODY DIMENSION B BODY DIMENSION C INSTALL BOLTS D INSTALL BOLTS E INSTALL BOLTS F INSTALL BOLTS G BASE FOOT H WATER RECEIVER 895 300 330 590 163 141 355 1013 14...

Page 16: ...ion 3 1 1 The manual operation mode is controlled through manual pad in the wind in take grid including such two modes as manual action and manual cooling Push the manual pad for each switchover the o...

Page 17: ...er to manual cooling mode 3 2 Heating Mode 3 2 1 Four way valve opens at once while defrosting process closes 3 2 2 Condition for the compressor action Ts set temperature Ta room temperature Condition...

Page 18: ...es 3 3 1 3 3 Temperature of outdoor coil T3 is up to 20 C 3 3 1 4 Ending Action of Defrost 3 3 1 4 1 Outdoor fan and four way valve are open 3 3 1 4 2 Compressor keeps on continuously 3 3 1 4 3 Indoor...

Page 19: ...3 6 4 Protective condition is actived 3 7 Fan Only Mode 3 7 1 Under this mode four way valve compressor and outdoor fan are shut down 3 7 2 High Low Auto fan can be switched over through manual contro...

Page 20: ...shut down for protection c When there are 4 times compressor protection within one hour the A C will be shut down meanwhile the operation light and timer light will be turned on the defrosting light...

Page 21: ...rent protection of the compressor occurs 4 times in 1h Lamps of operation timer defrosting only fan flashing simultaneously at 5Hz Whole unit is shut down It cannot recover unless power is cut off 2 p...

Page 22: ...4 C N 1 C N 24 R T2 R T1 T4 XT1 C AP1 FAN 1 L 3 2 N 1 N XT1 KM 1 KM 1 4 XT2 FSO 124HF Outdoor unit 4 W AY VALVE BLU E TO I N D O O R U N I T XT1 W H I TE BLU E BLAC K R ED Y G BLU E R ED Y G Y G BLAC...

Page 23: ...FSL 184HF Indoor unit FSO 184HF Outdoor unit 22...

Page 24: ...FSL 244HF Indoor unit 3 1 N L 2 XT1 XS1 XS3 XT1 XT2 CAP1 FAN1 XP1 XP3 RT2 RT1 CN1 CN16 T4 FSO 244HF Outdoor unit XT3 VALVE R T3 XT1 XT2 XS1 XP1 KM 1 FAN C AP2 C O M P C AP1 23...

Page 25: ...uit of the cool discharge Comply to the installation clearance recommended Don t put the indoor unit where there is direct sunlight on unit Make sure the location is suitable for piping and drainage F...

Page 26: ...pipe immediately in 5 minutes If the nuts have been loosened for a long time dusts and other impurities may enter the pipe system and may cause malfunction later So please expel the air out of the pi...

Page 27: ...age fits the rated voltage of the air conditioner There is no obstacle at the outlet and inlet of the outdoor and indoor units The gas side and liquid side stop values are both opened The air conditio...

Page 28: ...Cause Solutions Power failure Wait for the comeback of power Power switch is open Switch on the power Fuse of power switch may have blown Replace the fuse Batteries remote of controller are exhausted...

Page 29: ...ck whether the timer operation has come to an end when the OFF TIMER is indicated on the display The air conditioner operation stops since the set time elapsed The ON TIMER indicators go off after a l...

Page 30: ...lector 1 25 4 Wire joint 1 9 Capacity 1 25 5 Relay 1 10 Capacitor box 1 26 E Parts box cover 1 11 Right fixing clamp for motor 1 27 Pipe supporting board 1 12 Left fixing clamp for motor 1 28 Pipe cla...

Page 31: ...iring 1 7 Foam over holder for motor 1 25 Gas pipe valve 1 8 Cover 1 26 Liquid pipe valve 1 9 Fixing clamp for condenser 2 27 Separating board 1 10 Condenser 1 28 Compressor 1 11 Antivibration sponge...

Page 32: ...board II 1 10 Capacitor box 1 28 Holder for remote controller 1 11 Axis 1 29 Remote controller 1 12 Bearing 1 30 E Parts box cover 1 13 Bearing seat 1 31 Pipe supporting board 1 14 Fan ass y 3 32 Pip...

Page 33: ...egregator 1 9 Support board Left Side 1 26 Four way Valve 1 10 Rear Net 1 Four way Valve Solenoid 1 11 Support board Back side 1 27 High Pressure Valve 1 4 in 1 12 Handle 2 28 Capillary pipe Ass y 1 1...

Page 34: ...33 33...

Reviews: