5.6 Application conditions
Ambient
temperature range
without display
-20 °C … +60 °C
with display
-20 °C … +60 °C
Storage temperature range
-10 °C … +70 °C
Medium temperature range (in opera-
tion)
-10 °C … +85 °C
ATEX
EN 60079-0:2012 + A11:2013
EN 60079-15:2010
EMC
EN 61326-1:2013
EN 61326-2-3:2013
RoHS
EN 50581:2012
Type of protection:
IP 65 acc. to EN 60529
Materials of the parts that come into contact with the surroundings
Casing
CrNi Steel 1.4404, 1.4571
Process adapter TC
Clamp
light/solid
CrNi Steel 1.4404
High pressure
CrNi Steel 1.4308
TC clamp
CrNi steel 1.4301
Front pane
Safety composite glass
M12 plug
Ms nickel-plated, PA, FKM, Ms
Materials of the parts that come into contact with the measuring medium
Process adapter TC
Clamp
light/solid
CrNi Steel 1.4404
High pressure
CrNi Steel 1.4308
TC seal
FKM (Viton
®
)
Sensor membrane
Ceramics
Aluminium oxide ceramic Al
2
O
3
(99.9
%)
Piezo-resistive
CrNi 1.4435
5.7 Construction design.
All dimensions in mm unless otherwise stated
5.7.1 Dimensional picture
78
98.5
Ø72
Ø50.5
Fig. 12:
Dimension drawing