1.3.

Risks of Disregarding Safety Instructions

Disregarding  safety instructions, use of  this  product  for
purposes for which it is not intended, and/or operation of
this  product  outside  the  limits  specified  for  any  of  its
technical parameters, can result in harm to persons, the
environment, or the plant on which it is installed. Fischer
Mess-  und Regeltechnik  GmbH will  not  be responsible
for consequences in such circumstances.

1.4.

Safety Instructions for Operators

Safety instructions for the proper use of this product must
be  followed.  This  information  must  be  available  at  all
times by personnel responsible for installation, operation,
maintenance  and  inspection  of  this  product.  Adequate
steps  must  be  taken  to  prevent  the  occurrence  of
hazardous  conditions  that  can  be  caused  by  electric
energy and the convertible energy of the process media.
Such conditions can, for example, be the result of impro-
per electrical or process connections. Detailed informa-
tion  is  available  in  relevant  published  norms  (DIN  EN,
UVW  in  Germany;  and  equivalents  in other countries),
industrial  standards  such  as  DVWG,  Ex-,  GL-,  VDE
guidelines, as well as regulations of the local authorities
(e.g., EVUs in Germany).

The instrument must be put out of action and protected
against accidental use if safe operation can not be gua-
ranteed anymore. A reason for this might be one of the
following incidents:

apparent damage of instrument

failure of electrical function

longer  storage  periods  at  temperatures  higher  than
85 C

bad packaging during transport

Repairing  is only allowed to be done by  Fischer Mess-
und Regeltechnik GmbH.

Before  the  instrument  is  put  into  operation  again  a
professional  routine  test  acc.  to   DIN  EN61010,  part 1
needs to be done. This inspection should necessarily be
done by Fischer Mess- und Regeltechnik GmbH. Appro-
piate  transport  and  professional  storage  of  instrument
are understood.

1.5.

Modifications Forbidden

Modification or other technical alteration of the product is
not permissible. This also applies to the use of unautho-
rized spare parts for repair / maintenance of the product.
Any  modifications  to  this  product,  if  and  as  necessary,
should be done only by Fischer Mess- und Regeltechnik
GmbH.

1.6.

Operational Restrictions

The  operational  reliability  of  the  product  is  guaranteed
only when used for intended purposes. The product must

be  selected  and  configured  for  use  specifically  with
defined process media. The limiting values of operating
parameters, as given in the product specification sheet,
must never be crossed. 

1.7.

Safety Considerations during Installation and 
Maintenance

The safety instructions given in this manual, existing na-
tional regulations relating to accident prevention, and the
internal safety rules and procedures of the user organiza-
tion  regarding  safety  during  installation,  operation  and
servicing must all be followed meticulously.

It is the responsibility of the users to ensure that only su-
itably qualified and experienced technical personnel are
used  for  installation,  operation  and  servicing  of  this
equipment.

2.

Intended Applications

Display and limit detection of differential pressure of ga-
ses. The DE45  must  be  used only  for applications  and
under conditions specified by the manufacturer.

Classification of Explosion-Hazardous Area

The differential pressure switch / transmitter DE45 is su-
itable  as  „electrical  equipment  for  use  in  explosion-
hazardous areas (flammable gases)“, zone 2.

Declaration per Directive 94/9/EC (ATEX) 

 

 II  3 G  EEx nA IIC T4

            -10 C T

amb

60 C

3.

Product Description and Functions

3.1.

Functional Scheme

3.2.

Principles of Operation

The  instrument  is  based  on  a  piezo-resistive  sensor
element  and  can  measure  positive  gauge,  negative
gauge (vacuum) or differential pressure. The pressure is
measured directly by a piezo-resistive resistance bridge
that is formed on the surface of the integral silicon dia-
phragm  of  the  sensor.  Change  of  pressure  results  in
change  of  resistance  that  is  converted  to  a  varying
voltage  and  then  digitized.  The  instrument's  internal
microcontroller transfers the measured value on the LED

Contact: EK Engineering (India)
Web: www.ekeindia.com
Email: [email protected]

All manuals and user guides at all-guides.com

Summary of Contents for DE45 series

Page 1: ...d inspection of this product must have the qualifications training and experience necessary to carry out such work on this type of equipment Qualified personnel are people who are able to ju dge deleg...

Page 2: ...applies to the use of unautho rized spare parts for repair maintenance of the product Any modifications to this product if and as necessary should be done only by Fischer Mess und Regeltechnik GmbH 1...

Page 3: ...ing system must meet specifications for zone 2 class 3 Electrical connections must comply with relevant international and local regulations and norms re lating to electrical and instrumentation instal...

Page 4: ...lighted symbols to the right of the digital dis play To change the unit of measurement first press then search for parameter EIN using Next press again and select another unit of measurement using or...

Page 5: ...ut signal value set as parameter oEr However it should be understood that not all instrument fault and er ror conditions can be detected and signaled by the self diagnostic functions of the instrument...

Page 6: ...ast significant right most digit The value of the set up parameter R1D determines the delay time for switching output 1 after the measured value reaches the switching point The delay value can be sele...

Page 7: ...e measured variable corresponding with the minimum value of the output signal 0 V 0 mA or 4 mA depending on the instrument version ME Measuring range end point The value of the measured variable corre...

Page 8: ...the instruments Inspection and test schedules depend on operating and site conditions The operating manuals of other equip ment to which the transmitter is connected must be read thoroughly to ensure...

Page 9: ...20 70 C IP 65 acc to DIN EN 60529 Electrical Data Nominal supply voltage Operating supply voltage Output signal 24 V DC AC 12 32 V DC AC 0 20 mA 4 20 mA 0 10 V DC 3 wire Output signal load For output...

Page 10: ...h 1 2 activation point de activation point response time delay 0 0 100 0 secs logic N O or N C Measurement unit selection mbar Pa free unit start value end value and decimal place for free unit Zero s...

Page 11: ...ge output 0 10 V DC linear 3 wire C Current output 4 20 mA linear 3 wire P Supply Voltage 24 V DC AC nominal 12 32 V DC AC K Display Switching output 3 digit LED 2 potential free semiconductor switch...

Page 12: ...12 14 Declaration of Conformity Contact EK Engineering India Web www ekeindia com Email india eke gmail com All manuals and user guides at all guides com...

Reviews: