FISCHER DE45 series Data Sheet And Instruction Manual Download Page 11

11

13.

Ordering Code

Digital Differential Pressure Switch / Transmitter

 DE45

0

0

K 0

M

R

####

0 ...

4 mbar ........................... 50 mbar........................

5

2

0 ...

6 mbar ........................... 50 mbar........................

5

3

0 ...

10 mbar ......................... 100 mbar........................

5

4

0 ...

16 mbar ......................... 100 mbar........................

5

5

0 ...

25 mbar ......................... 250 mbar........................

5

6

0 ...

40 mbar ......................... 250 mbar........................

5

7

0 ...

60 mbar ......................... 500 mbar........................

5

8

0 ...

100 mbar ......................... 500 mbar........................

5

9

0 ...

160 mbar ....................... 1500 mbar........................

6

0

0 ...

250 mbar ....................... 1500 mbar........................

8

2

-2,5 ... +2,5 mbar ........................... 50 mbar........................

A

6

-4 ...

+4 mbar........................... 50 mbar........................

A

7

-6 ...

+6 mbar......................... 100 mbar........................

A

8

-10 ...

+10 mbar......................... 100 mbar........................

A

9

-16 ...

+16 mbar......................... 250 mbar........................

B

1

-25 ...

+25 mbar......................... 250 mbar........................

B

2

-40 ...

+40 mbar......................... 500 mbar........................

C

5

-60 ...

+60 mbar......................... 500 mbar........................

B

3

Pressure Connections

Threaded hose clamp connectors for 6 / 4 mm hose ..................................................

4

0

Threaded hose clamp connectors for 8 / 6 mm hose ..................................................

4

1

Signal Output

No signal output ............................................................................................................................

0

Current output: 0 - 20 mA linear, 3-wire........................................................................................

A

Voltage output: 0 - 10 V DC linear, 3-wire .................................................................................... C

Current output: 4 - 20 mA linear, 3-wire........................................................................................

P

Supply Voltage

24 V DC/AC nominal (12-32 V DC/AC) ................................................................................................

K

Display

Switching output

3½-digit LED

2 potential-free semiconductor switch ...............................................

6

Electrical connection

M12 connector ............................................................................................................................................................... M

Installation

Rear cover anchor points.......................................................................................................................................................

0

Set for panel mounting...........................................................................................................................................................

T

Wall mounting ........................................................................................................................................................................

W

Customized Number

Marking for usage in zone 2 - hazardous gases :  

 II 3G Ex nA IIC T4 ......................................................................

R####

13.1. Accessories

Ordering Code

Designation

Pins

Application

Length

06401993

cable with M12 connector

4-pin

for relay / switch

2 m

06401994

cable with M12 connector

4-pin

for relay / switch

5 m

06401995

cable with M12 connector

5-pin

for supply / signal

2 m

06401996

cable with M12 connector

5-pin

for supply / signal

5 m

EU03.F300

PC-programming interface with SW

Contact: EK Engineering (India)
Web: www.ekeindia.com
Email: [email protected]

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for DE45 series

Page 1: ...d inspection of this product must have the qualifications training and experience necessary to carry out such work on this type of equipment Qualified personnel are people who are able to ju dge deleg...

Page 2: ...applies to the use of unautho rized spare parts for repair maintenance of the product Any modifications to this product if and as necessary should be done only by Fischer Mess und Regeltechnik GmbH 1...

Page 3: ...ing system must meet specifications for zone 2 class 3 Electrical connections must comply with relevant international and local regulations and norms re lating to electrical and instrumentation instal...

Page 4: ...lighted symbols to the right of the digital dis play To change the unit of measurement first press then search for parameter EIN using Next press again and select another unit of measurement using or...

Page 5: ...ut signal value set as parameter oEr However it should be understood that not all instrument fault and er ror conditions can be detected and signaled by the self diagnostic functions of the instrument...

Page 6: ...ast significant right most digit The value of the set up parameter R1D determines the delay time for switching output 1 after the measured value reaches the switching point The delay value can be sele...

Page 7: ...e measured variable corresponding with the minimum value of the output signal 0 V 0 mA or 4 mA depending on the instrument version ME Measuring range end point The value of the measured variable corre...

Page 8: ...the instruments Inspection and test schedules depend on operating and site conditions The operating manuals of other equip ment to which the transmitter is connected must be read thoroughly to ensure...

Page 9: ...20 70 C IP 65 acc to DIN EN 60529 Electrical Data Nominal supply voltage Operating supply voltage Output signal 24 V DC AC 12 32 V DC AC 0 20 mA 4 20 mA 0 10 V DC 3 wire Output signal load For output...

Page 10: ...h 1 2 activation point de activation point response time delay 0 0 100 0 secs logic N O or N C Measurement unit selection mbar Pa free unit start value end value and decimal place for free unit Zero s...

Page 11: ...ge output 0 10 V DC linear 3 wire C Current output 4 20 mA linear 3 wire P Supply Voltage 24 V DC AC nominal 12 32 V DC AC K Display Switching output 3 digit LED 2 potential free semiconductor switch...

Page 12: ...12 14 Declaration of Conformity Contact EK Engineering India Web www ekeindia com Email india eke gmail com All manuals and user guides at all guides com...

Reviews: