![Fischer Panda Panda AGT/DC 10000 PMS Operation Manual Download Page 29](http://html1.mh-extra.com/html/fischer-panda/panda-agt-dc-10000-pms/panda-agt-dc-10000-pms_operation-manual_2294288029.webp)
The Panda Generator
Panda PMS AGT-DC 10000 - Chapter A: The Panda Generator Page 23
Terminal block for remote control cable
with fuses and power relais
F1 fuse 15A for DC
F2 fuse 25A for starter
Ks relay for starter
K2 relay for glow plugs
K3 relay for fuel pump
Fig. A.44: Terminal block
Fuse for measuring voltage
Fig. A.45: Fuse for measuring voltage
A.2.7 Sensors and switches for operating surveillance
Thermo-switch at cylinder head
The thermo-switch at the cylinder head
serves the monitoring of the generator
temperature. All thermo-switches for the
generators from Panda 6.000 upward are
two-pole and laidout as "openers".
Fig. A.46: Thermo-switch at cylinder head
F1
F2
Ks
K2
K3