The Panda Generator
Page 16 Panda PMS AGT-DC 10000 - Chapter A: The Panda Generator
Glow plugs
The glow plugs serve the pre-chamber for
the heating with cold start. The heat-treat
fixture must be operated, if the tempera-
ture of the generator is under 16°C. This
is practically with each start the case. The
heat-treat fixture may be held down also
during start and favoured the starting pro-
cedure.
Fig. A.23: Glow plugs
Stop solenoid for engine stop
Some model are additional equipped with
an stop solenoid. The generator is stop-
ped by the co-operation of the stop sole-
noid immediately after switching off. The
adjustment of the stop solenoid must
always be checked, in order to be sure
that the stop lever can move also during
the operation freely and is not under pre-
stressing.
Fig. A.24: Stop solenoid
A.2.5 Components of combustion air
Air suction openings at the sound
cover
The sound cover is provided at the upper
surface with drillings, through which the
combustion air can influx.
It must be consistently paid attention that
the generator is installed in such a way
that from no water can arrive into the pro-
ximity of these air openings. (minimum
distance 150 mm)
Fig. A.25: Combustion air intake