Generator Failure
Page 78 AGT 6000 PVMV-N 12V_24V - Chapter D: Generator Failure
D.1.1 Automatic Voltage Monitoring and Auto-Shut Down
If air conditioning units (compressors) or other such valuable equipment are installed on-board,
an automatic voltage monitoring unit should be installed to protect this equipment from possible
sharp voltage drops. The voltage monitoring system shuts down the entire system (and therefore
all users) through a circuit breaker relay as soon as the voltage falls below a set value (the moni-
tor will also shut down the on board grid automatically when the generator is stopped). The moni-
toring system also switches the grid back on once the required voltage level is again reached.
This ensures no damage is caused to the consumers and fittings through undervoltage. Such a
voltage relay can be obtained from wholesale dealers or as a complete unit from PANDA dealers.
The circuit is always automatically cut off if the generator is stopped.
D.1.2 Adjusting Instructions for the Spindle of the actuator
There are two independent regulation devices for the rev range of the generator. Limited upward
and downward:
• With the regulation nuts at the spindle of the actuator left and right of the spindle nut.
• With an adjusting screw directly at the base of the rev regulator lever. (only up)
After all work at the components of the rev regulation is done the adjustment of the limitation must
be checked.
ATTENTION! Special caution, rotary sections can be touched.
01. Actuator
02. Spiral thread spindle
03. Regulating nuts max. revolution
04. Spindle nut with rev regulator lever
05. Regulating nuts min. revolution
Fig. D.1.2-1: Actuator
During any operation at the generator all consumers have to be switched off to avoid damages at
the equipments.
01
02
03
04
05
Summary of Contents for AGT 6000 PVMV-N
Page 1: ...Panda AGT 6000 PVMV N Super silent technology 24V 6kW Fischer Panda GmbH ...
Page 6: ......
Page 10: ...8 Socket wrench set Hexagon wrench keys ...
Page 92: ...Generator Failure Page 90 AGT 6000 PVMV N 12V_24V Chapter D Generator Failure ...
Page 100: ...Appendix Page 98 AGT 6000 PVMV N 12V_24V Chapter E Appendix ...
Page 102: ...Page 100 AGT 6000 PVMV N 12V_24V Chapter E E 6 Capsule Measurements ...
Page 106: ...VCS AGT U I Page 104 Chapter A VCS AGT U I VCS AGT UI_eng fm Fischer Panda Datasheet blank ...