13.8 F. U.V. lamp disinfection system.
ULTRAVIOLET LAMP.
Concerns related to pathogenic organisms in the water causing illnesses and
contaminating industrial processes, have led FISAIR S.L.U to provide the optional
integration of ultraviolet technology in its evaporative units. This type of system
eliminates bacteria, viruses and other pathogens, prevents their reproduction, and
results in completely safe drinking water.
U.V. radiation is one band of the electromagnetic spectrum. It has more energy than
visible light. The irradiation of germs present in the water with U.V. light harms their
DNA molecules (figure 1) in a number of ways, which prevents cell division and kills
them. The most harmful radiation for germs has a wavelength of 254 nanometres.
The DNA exposed to this energy can only absorb up to a maximum, after which there
is an irreparable inactivation of the growth of the pathogens.
13.8
F1. External fill/water supply UV lamp disinfection system. (For direct water)
ULTRAVIOLET LIGHT DISINFECTION WATER FILTERS
The
only control panel included as standard is the one that comes with the UV lamp itself.
(Figure 2).
Summary of Contents for HEF2 SERIES
Page 2: ...HEF2 Series MANUAL 2...
Page 13: ...HEF2 Series MANUAL 13 Machine type rating plate Partly completed machinery type rating plate...
Page 66: ...HEF2 Series MANUAL 66 Wiring Diagram connections Dimensions GDB13 1 GDB13 1...
Page 67: ...HEF2 Series MANUAL 67 Adjusting A B Auxiliary contacts...
Page 69: ...HEF2 Series MANUAL 69 Wiring Diagram connections Dimensions...
Page 70: ...HEF2 Series MANUAL 70 Manual positioning...
Page 76: ...HEF2 Series MANUAL 76 13 9 G Perimeter closures cover plates dimensional drawings...
Page 78: ...HEF2 Series MANUAL 78 Dimensional drawing for Top Cover Plates...
Page 98: ...HEF2 Series MANUAL 98 H1 ON OFF or BUS...
Page 101: ...HEF2 Series MANUAL 101 1 Cassette ON 2 Cassettes ON 3 Cassettes ON Ideal Stage Control...
Page 102: ...HEF2 Series MANUAL 102 Control by stages or control ON OFF...
Page 103: ...HEF2 Series MANUAL 103 H1 ON OFF 0 10Vcc regulated or BUS...
Page 105: ...HEF2 Series MANUAL 105 Dew point control Dew point control...
Page 106: ...HEF2 Series MANUAL 106 H1 ON OFF or BUS...
Page 117: ...HEF2 Series MANUAL 117...
Page 120: ...HEF2 Series MANUAL 120 Remove the PP R D25 piping to the header PP R D25 pipe...
Page 121: ...HEF2 Series MANUAL 121...
Page 122: ...HEF2 Series MANUAL 122...
Page 123: ...HEF2 Series MANUAL 123...
Page 125: ...HEF2 Series MANUAL 125...
Page 126: ...HEF2 Series MANUAL 126 23 CLEANING THE INDIVIDUAL IRRIGATION SYSTEM...
Page 127: ...HEF2 Series MANUAL 127...
Page 128: ...HEF2 Series MANUAL 128 24 LIST OF SPARE PARTS...