OXY2-OXY2E Instruction Manual 180122.docx 

 

 

 

 

 

OXY2 & OXY2E Series 

Iron Reduction System 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation Instructions and Owner’s Manual 

Summary of Contents for OXY2-10

Page 1: ...s LLC 12630 US Highway 33 N Churubusco IN 46723 Phone 260 693 1972 Fax 260 693 0602 OXY2 OXY2E Instruction Manual 180122 docx OXY2 OXY2E Series Iron Reduction System Installation Instructions and Owne...

Page 2: ...ng Time of Day Page 11 OXY2E Programming Page 12 Specifications Page 13 Component Parts Breakdown List Page 14 OXY2 Control Valve Breakdown Page 15 OXY2 Control Valve Parts List Page 16 OXY2E Control...

Page 3: ...ither clear water ferrous state red water ferric state or bacterial form The OXY2 iron filter can reduce any of these forms of iron Manganese A naturally occurring metallic element Manganese concentra...

Page 4: ...optimum filter performance and satisfactory water quality The following factors should be considered in selecting the location of the iron filter 1 The filter should be installed after the pressure t...

Page 5: ...e ground leg of the electric supply continuity should be maintained by installing ground straps around any non conductive plastic piping or bypass used in the installation Make sure the filter is not...

Page 6: ...with silicone lubricant and screw the control valve onto the filter tank STEP 6 Shut off water at main supply Relieve pressure by opening nearest faucet On private well systems turn off power to pump...

Page 7: ...the Service position Figure 3 page 4 STEP 11 Remove media fines by manually initiating regeneration For the OXY2 turn the manual backwash knob Figure 4 page 8 clockwise until the drive gear engages t...

Page 8: ...each screw slightly to release pressure on the 24 Hour gear time plate d Continue depressing the red Time Set Button and rotate the 24 Hour Gear to expose the Regeneration Time Pointer Figure 4a page...

Page 9: ...ts a day The number by the red pointer is tonight 3 Slide the metal tabs outward on the desired days of regeneration The OXY2 Filter should be set to backwash a minimum of every third day How to Manua...

Page 10: ...by shifting both the backwash pins and air draw holes an equal number of positions counter clockwise on the program wheel 4 AIR DRAW cycle may be lengthened by increasing the number of holes between...

Page 11: ...seconds to initiate an immediate regeneration cycle 2 Press and release Advance Button during a regeneration cycle to immediately advance the valve to the next step in the regeneration process 3 When...

Page 12: ...Use Up Button to set current hour Use Up Button to set current minute Use Up Button to set AM PM Default setting is 20 GPG This iron filter does not meter the water use Adjusting the water hardness s...

Page 13: ...egenerating Use Up Button to set minutes for time of backwash Use Up Button to set AM or PM for time of backwash The DEFAULT setting is not used for OXY2E iron filters and must be set to OFF Default c...

Page 14: ...ME cu ft 1 0 2 0 GRAVEL UNDERBED lbs 20 30 SERVICE FLOW RATES gpm Continuous 5 gpm ft 2 gpm 3 5 Peak 16 gpm ft 2 gpm 9 13 PRESSURE LOSS 1 psi Continuous Flow Rate 5 7 Peak Flow Rate 10 13 REGEN FLOW R...

Page 15: ...k Control Valve includes bypass valve OXY2E 10 Vlv Assy W BP OXY2E 20 Vlv Assy W BP Complete Electronic Control Valve includes bypass valve 2 D100S 54 Distributor Tube 1 x 54 3 MTP1054N MTP1354N Miner...

Page 16: ...15 OXY2 Control Valve Breakdown...

Page 17: ...ton Assembly 19 13304 Distributor O Ring 121 H FV2510 1PH Power Head Assembly 2510 TC with Cover 20 13030 Distributor Retainer I 60050 21 Drive Motor Assembly Not Shown 40027 J tube for 2510 valve Old...

Page 18: ...17 OXY2E Control Valve Breakdown...

Page 19: ...19936 Base Seal 2510 H 60160 10 Drive Cam Assembly STF 16 19322 2510 Adapter Base I 60308 13 2510E Timer Assembly 17 19197 Slip Ring J 60011 050ASSY Brine Valve 1650 Short Stem 0 5 BLFC with Tube 18...

Page 20: ...eded 2 Replace spacers and seals 3 Verify distributor tube seated securely in control valve body 4 Verify actual water usage flow rates against system specifications 5 Verify adequate pumping rate for...

Page 21: ...ly C Debris in control valve D Internal leak in control valve E Drive motor faulty 1 Ensure electrical outlet is functioning 2 Verify timer programming 3 Disassemble and clean control valve 4 Replace...

Page 22: ...21 Control Valve Wiring...

Page 23: ...unction occur contact the dealer that you purchased the product from If you are unable to contact the dealer contact First Sales LLC 260 693 1972 We will require a full description of the problem mode...