1.

 

WARNINGS 

 

Your C-RED 2 camera contains fragile components, handle it with care. 

 
 

Do not open the camera, your warranty will be void. 

 

 

Always use the supplied power unit. 

 
 

Always follow the instructions of use.  

 

 

2.

 

SYMBOLS AND INDICATIONS 

 

Please read this Quick Start guide and the following definitions carefully to understand the potential dangers 
and the precautions to take.   
Please refer to the User Manual if a WARNING symbol is marked on the camera.  

 

 

The CE marking indicates the conformity of the camera to the European legislation 

 

 This pictogram indicates a direct current operation 

 

This pictogram invites the user to refer to the instructions / user manual 
 
This pictogram refers to indoor use   
 
This pictogram refers to Protection class category 1 
 
This pictogram indicates that the product is compliant with the RoHS limitation 

 

 

 

Summary of Contents for C-RED 2

Page 1: ...C RED 2 Quick Start Manual C RED 2 Quick Start_20180622...

Page 2: ......

Page 3: ...the instructions of use 2 SYMBOLS AND INDICATIONS Please read this Quick Start guide and the following definitions carefully to understand the potential dangers and the precautions to take Please refe...

Page 4: ...the system assembler only For your safety the equipment must be TURNED OFF AND UNPLUGGED before any technical intervention The security provided with this equipment is only guaranteed with a use in a...

Page 5: ...rent accessory packs Items may differ from pictures Item name Quantity Picture Camera 1 Power supply 1 IEC cable 1 USB C to USB A cable 1 USB key with User manual Demo software Test report 1 Quick sta...

Page 6: ...l mode Liquid cooling 1 allows to cool the detector down to nominal 40 C with the following conditions Cooling System Parameters Value Flow rate 0 5 L min Pressure 10 bar max Liquid Temperature 35 C m...

Page 7: ...ted with specific grabbers that we highly recommend using Please refer to the demo software manual List of tested recommended grabbers MATROX Radient eV cl full Teledyne DALSA X64 Xcelera CL Windows o...

Page 8: ...cription Configuring Blue Camera starting Operational Green Camera configuration is applied Operational cooling White Camera is cooling down Operational cold Purple Camera has reached target temperatu...

Page 9: ...adout function The acquisition speed can be set to any value from 0 001 to 600 fps The integration time can also be set The integration time range is 50 s 1 fps For integration time below 50 s please...

Page 10: ...e protection on all power lines Any connected equipment should be powered off before removing any connection between the computer and C RED 2 14 MAINTENANCE Cleaning of window Never use an unclean clo...

Page 11: ...2138 USA Tel 33 4 42 61 29 20 E mail support first light fr Website www first light us For the rest of the world FIRST LIGHT IMAGING SAS Europarc Sainte Victoire B t 6 Route de Valbrillant Le Canet 13...

Page 12: ...Notes...

Page 13: ...Notes...

Page 14: ......

Reviews: