Table 9 - Thermal management performances and temperature minimum set point
Power supply
Cooling method
Air
temperature
Water
temperature
Sensor
minimum
set point
External power
supply
Air cooling, fan at full speed
< 35°C
-
10°C
Air cooling, fan at full speed
< 45°C
-
20°C
Water cooling / no fan
<45°C
< 45°C
10°C
PoCXP
Water cooling / no fan
≤ 30°C
< 40°C
10°C
The temperature maximum set points are:
10°C below the ambient air temperature, in the case of air cooling
10°C below the water temperature, in the case of water cooling
Electronics protection
In case of overheating or too cold temperature depending on external operating conditions, the camera
will automatically shut itself down to protect electronic components.
Please note that it is not possible to switch off this functionality.
The internal firmware monitors at each time the temperatures on different parts and boards. Each
temperature must be within the accepted range.
Before shutting down the camera, the firmware tries to limit the power consumption of the camera to
decrease the heat that is generated.
To recover the use of the camera, after the camera went back in the authorized range of temperature,
the user must reboot the camera by unplugging/plugging the power.