12
1.Set Adjuster handle to “MIN”
2.Row at least ten strokes to fill the storage reservoir as completely as possible.
3.Remove Tank Plug.
4.Insert rigid end of siphon into the tank, and flexible hose into a large bucket
.
5.Drain tank (approx. 40% of water will remain) and then refill following directions
for Tank filling as described in the Tank Filling section of this manual.
Note
:The valve on top of the siphon must be closed to allow proper drain
age.
Note
:Water treatment will preclude the need to change tank water if the treat-
ment schedule is maintained. Additional chlorine is required only when dis-
coloration appears in the water.
Note
:Exposure to sunlight affects the water. Moving the rower away from direct
sunlight .
Rigid end of Siphon in tank
To Change Tank Water
Set Adjuster handle to “MIN”
Row a minimum of ten complete strokes before com-
mencing tank draining. Remove tank plug, insert rigid
end of siphon into tank and begin draining.
NOTE: Approximately 40% of tank water will remain. It is
not possible to completely drain the A/R tank without dis-
assembly.
Removing/Changing Tank Water