8
If required, follow these steps
1.
Remove the batteries from the console.
2.
While reinserting the batteries
press and hold the RESET and UP buttons for 3+ seconds.
3.
The console will beep twice and the select equipment screen will be displayed.
4.
The
CAL field shows the currently selected equipment
.
SPECIAL FUNCTIONS
EQUIPMENT SELECTION
The correct equipment type is set at the factory as part of the manufacturing process so this
procedure should not be required by an end user under normal circumstances.
EQUIPMENT ID IN CAL WINDOW
EQUIPMENT ID
3000
Fluid Exercise -
E650
ARM CYCLE
3001
Fluid Exercise -
E750
CYCLE UBE
3002
Fluid Exercise -
E850
UBE
3003
Fluid Exercise -
E950
MEDICAL UBE
5.
Use the
UP
and
DOWN
buttons to select the required equipment.
6.
Press
RESET
to confirm selection and the console will reboot with the selected configuration.
HOLD TO REST
SELECT EQUIPMENT