If needed the following procedure is to calibration the resistance level sensory.
TO DO THIS FOLLOW THESE STEPS.
1.
Power on the console.
2.
Press and hold REST and DOWN for 3+ seconds.
3.
The console will beep once and display the calibration screen.
4.
Set the Fluid Resistance to level 1 and wait a few seconds before clicking RESET.
5.
Set the Fluid Resistance to level 2 and wait a few seconds before clicking RESET.
6.
Set the Fluid Resistance to the next level and wait a few seconds before clicking RESET.
7.
Repeat #6 until all levels have been done (5 or 10 depending on Fluid Resistance Tank).
8.
When all levels are done the console will reboot.
9.
Check calibration by cycling through all resistance levels.
*The numbers below is a non realistic
example of calibration of a 5 level tank
FLUID RESISTANCE LEVEL CALIBRATION PROCEDURE
LEVEL 5
HORIZONTAL
LEVEL 10
ANGLED OR VERTICAL
LEVEL 10
XL HORIZONTAL
FDF - FLUID ROWER - FLUID RESISTANCE TWIN TANKS