22
Troubleshooting
Fault
Probable Cause
Solution
Water changes color
or becomes cloudy.
Rower is in direct
sunlight or has not had
water treatment.
Change Rower location to reduce direct
exposure to sunlight. Add water treatment
or change Tank water as directed in the
water treatment section of this manual.
Consider using distilled water to refill Tank.
Rowing stroke return
is too light.
Bungee not under enough
tension.
Rowing Belt missing one
wrap around Rower belt
pulley.
Bungee has slipped off
the Bungee Pulley Wheel.
Cut Bungee Tie Rack and tighten slightly on
Bungee Hook.
Monitor screen
illuminates, but does
not register when
rowing.
Loose or failed
connection/Sensor gap
too wide (see erratic
Monitor display).
Check that the Monitor lead is connected
properly. If connected properly check Sensor
gap. Contact your local service center if this
fails to address the problem.
Belt can’t extend to
the end of rowing
stroke or no
resistance.
Rowing Belt needs to be
unwrapped 1 turn or,
requires an extra wrap
on the Rower Belt Pulley
The Monitor does not
illuminate after
battery installation.
Batteries installed
incorrectly or need
replacing.
Reinstall batteries in correct position and try
again. If the LCD screen fails to illuminate,
try rotating the batteries slightly in the
Monitor. If this fails, contact your local ser-
vice center.
The Monitor display
is erratic while
displaying SPM and
500meter times.
Gap between Sensor and
Magnetic Ring is too
wide.
The Monitor LEVEL is
not synchronized
with the Tank LEVEL.
Monitor LEVEL needs to
be recalibrated.
Please refer to "Calibration Procedure" page
19 of this manual.
Remove large service cover and check gap
between Sensor and Magnetic Ring (should be
no more than 2.5mm).