IS329 ECN3592
6
INSTALLATION
SITING
The installer must ensure that all regulations are met and that there is an unobstructed
minimum distance of 1000mm from the top of the flue to the ceiling, which must be of non-
combustible material.
The appliance should be installed on a level surface ensuring the unit is stable and firmly
located.
Any partitions, walls or kitchen furniture in close proximity must be of non-combustible
materials and not be closer than 50mm from the sides and rear of the flue.
GAS SUPPLY AND CONNECTION
Connection is at the rear of the unit via a 1/2" G male thread.
Connection shall comply with local regulations. The gas supply tubing or hose should be
periodically inspected and replaced as necessary.
When making the connection to the appliance an isolating cock should be fitted into the
supply line close to the unit, for emergency shutdown or servicing purposes.
SUPPLY PRESSURES
To gain access to the gas pressure test nipple open both oven doors. The nipple is
situated beneath the fascia panel on the left of centre.
Remove the blanking screw and attach a pressure gauge to the boss of the test
nipple.
For Natural gas appliances only. Light the oven burner only, thermostat set to
maximum.
Adjust the pressure at the governor. See table.
LOCKING OF WHEELS
When the appliance has been installed in its intended position the front casters should be
locked by depressing the locking tabs on the castors.
Locks should only be released for the intention of moving the appliance for
cleaning purposes and or routine servicing of the appliance.