14. FBL770BC PIN Description
–
Major control port
PIO 7
PIO 6
Reset
TX
ADC0
ADC1
Advertising status
Advertising control
Ant
NC
NC
DC
DD
NC
NC
NC
P
IO
5
P
IO
4
P
IO
3
P
IO
2
P
IO
0
/
P
W
M
0
V
C
C
Power Save control
P
IO
1
/
P
W
M
1
Power Save status
RX
GND
Top
Bottom
Item
Port
Details of operation
(For further detail on the method of use, please refer to the FBL770BC user manual.)
Major
Control port
Advertising control
It is used to select On/Off of FBL770’s Advertising function.
Remarks: Initial Advertising function status after powering on FBL770 is On.
Advertising status
It is used to monitor the status of Advertising operation of FBL770.
Power Save control
Select On/Off of FBL770’s Power Save function.
Power Save status
It is used to monitor the status of power save operation of FBL770.
Remarks: After powering FBL770 on, the initial Power Save function status is On. (For further details on the
method of use, please refer to the FBL770BC user manual.)
Reset
When Reset (Active low) signal is supplied, hardware reset of FB770BC occurs.