background image

The followings are displayed on hyper terminal 

connected with FB100AS to be reset.

* Factory Reset Progress – Environment Setup Menu Confirmation

Summary of Contents for FB100AS

Page 1: ...FB100AS Quick Guide...

Page 2: ...Features of FB100AS...

Page 3: ...tific Medical Bluetooth uses a 1Mbps 3Mbps wireless transmission speed Bluetooth consists of Master Slave configuration as the relation between Master and Servant and one bluetooth device can be conne...

Page 4: ...trol possible 2400bps 230400bps by using Dip Switch Master Slave setup possible by using Dip Switch Supports AT command and AT command based control available Connects smoothly with Bluetooth PDA Blue...

Page 5: ...rds the progressive method of this FB100AS Quick Guide guides the user in order from the start 4 Thus if you read this guide for the first time you need to proceed chapter by chapter in order to corre...

Page 6: ...Index 0 Product Content Installation 1 Hyper Terminal Setup 2 FB100AS Operation 3 Master Slave Setup 4 Connect 5 Serial Data Transmission 6 Disconnect 7 Re connect...

Page 7: ...0 Product Content Installation...

Page 8: ...1 FB100AS Content Product Content in One Set FB100AS Antenna 4 dBi Gain USB Power Cable 1 Product Content in One Set of FB100AS FB100AS Type 1 Set...

Page 9: ...2 Configuration Using 2 Sets FB100AS Quick Guide uses two devices for explanation purpose 1 set for master setup 1 set for Slave setup...

Page 10: ...re FB100AS Operation Dip Switch Number 1 ON Basic Setup Agenda Dip Switch Number 2 3 4 OFF Dip Switch Number 3 4 ON Basic Setup Agenda UART communication speed setup to 9600bps For even more details o...

Page 11: ...1 FB100AS Antenna USB Power Cable PC 3 Product Installation Connect two FB100AS to a PC In this FB100AS Quick Guide two FB100AS are connected to one PC for convenient explanation...

Page 12: ...1 Setup of Hyper Terminal Checking received data operation status by using hyper terminals...

Page 13: ...Operating A Hyper Terminal 1 Serial Communication Program Hyper Terminal Execution Setup Click Start on Windows Start menu Click All Programs Click Accessories Click Communications Click Hyper Termin...

Page 14: ...al connected to FB100AS to be set up to Master Enter Master as a name Click OK and proceed to the next step Select a port to be connected to FB100AS set up to Master Assumed here as COM1 Click OK and...

Page 15: ...4 Setup of Hyper Terminal Communication Speed etc Select 9600 for Bits per Second B Select None for Flow Control F No change for other items Click OK...

Page 16: ...al Finish Setup of Hyper Terminal connected to the FB100AS to be set as Master is completed Do the setting of the hyper terminal connected to the FB100AS to be set to a name of slave in the same way a...

Page 17: ...2 Operating FB100AS...

Page 18: ...Press ON of Power Switch 1 FB100AS Power Supply ON 1 Operating the FB100AS...

Page 19: ...2 Hyper Terminal Output Screen Turn on the power switches of all two FB100AS You can see BTWIN Slave mode start displayed on the screen Turn off the power switches of all devices...

Page 20: ...s LED is displayed a green light if FB100AS is on Operation Mode Operation Status LED is displayed a red light if FB100AS is on configuration Mode Setup Power LED is displayed a red light if FB100AS p...

Page 21: ...when FB100AS does not operate normally nor any words is displayed on hyper terminal Restart the FB100AS by cycle power off and then on of FB100AS power switch Confirm communication speed other connect...

Page 22: ...POWER LED Status LED Condition Operated Normally Status LED is blink a green Power LED is ON a red...

Page 23: ...not care for other Dip Switch condition FB100AS Electricity Power ON Factory Reset Progress Environment Setup Entry by using Dip Switch Instructions Quick Guide is based on factory reset value If it...

Page 24: ...The followings are displayed on hyper terminal connected with FB100AS to be reset Factory Reset Progress Environment Setup Menu Confirmation...

Page 25: ...Power LED Status LED Condition Entried into Environment Setup Mode Status LED is blink a red Power LED is ON a red...

Page 26: ...p message output is made on the hyper terminal connected with FB100AS to be reset Confirm RESET of a side FB100AS Press a Reset Switch in hole by using tweezers FB100AS was reset if environment setup...

Page 27: ...3 Master Slave Setup...

Page 28: ...ss ON of Dip Switch Number 1 Basic setup agendas Press OFF of Dip Switch Number 2 3 4 FB100AS electricity power ON In case of factory reset value slave is basically setup No need to be changed here 1...

Page 29: ...slave BTWIN Slave mode start output is made from the FB100AS Slave setup is finished In case of factory reset value slave is basically setup No need to be changed here FB100AS Slave scans at the same...

Page 30: ...LED Condition Operated By Slave Status LED is blink a green Power LED is ON a red...

Page 31: ...AS is setup as follows Press ON of Dip Switch Number 1 Basic setup agendas Press ON of Dip Switch Number 3 Press OFF of Dip Switch Number 2 4 FB100AS electricity power ON 1 FB100AS master Setup 2 Mast...

Page 32: ...e FB100AS set up to master BTWIN Slave mode start output is made from the FB100AS Master setup is finished FB100AS Master is being connected at the same time of operating Connected immediately if devi...

Page 33: ...Status LED Condition Operated By Master Status LED is blink a green Power LED is ON a red...

Page 34: ...4 Connect...

Page 35: ...r CONNECT 00189AF467DD output is made from the FB100AS Bluetooth Address displays the connection with 00189AF467DD device Enter the following on the hyper terminal connected to the FB100AS set up to s...

Page 36: ...Status LED Condition Connected Status LED is ON a green Power LED is ON a red...

Page 37: ...f Master or Slave is connected with new device again Should be progressed again from the start after all FB100AS reset if the connection of FB100AS Master Slave is not progressed for a certain time In...

Page 38: ...p Switch to be reset of FB100AS is setup as follows Press ON of Dip Switch Number 4 Does not care for other Dip Switch Condition FB100AS electricity power ON Environment Setup Entry by using Dip Switc...

Page 39: ...The left message is displayed on hyper terminal connected with FB100AS to be reset Environment Setup Menu Confirmation...

Page 40: ...LED Condition Entried by Environment Setup Status LED is blink a red Power LED is ON a red...

Page 41: ...utput is made on the hyper terminal connected with FB100AS to be reset Confirm RESET of a side FB100AS Press a Reset Switch in hole by using tweezers FB100AS was reset if environment setup message out...

Page 42: ...5 Serial Data Transmission...

Page 43: ...n on the hyper terminal Enter the followings on the hyper terminal connected to FB100AS setup to be master After entering 123456789 on the hyper terminal press enter key Entered data is not shown on t...

Page 44: ...3456789 is shown on the hyper terminal Enter the followings on the hyper terminal connected to FB100AS setup to be slave After entering 123456789 on the hyper terminal press enter key Entered data is...

Page 45: ...6 Disconnect...

Page 46: ...FB100AS Master Slave are disconnected automatically after a certain time if one side of FB100AS electricity power is OFF 1 Disconnect Method...

Page 47: ...7 Re connect...

Page 48: ...1 Reconnect Method Reconnected automatically again if electricity power of FB100AS device is ON in case of previously connected FB100AS Master Slave...

Page 49: ...For even more details please refer to FB100AS user mannual...

Reviews: