WHEN OPERATING EQUIPMENT

DO  NOT

  operate  this  product  inside  any

building, carport, porch, mobile equipment,
marine applications, or enclosure.

DO NOT

 tip engine or equipment at angle

which causes fuel to spill.

DO NOT

 stop engine by moving choke

control to “Start” position.

WHEN TRANSPORTING, MOVING
OR REPAIRING EQUIPMENT

Transport/move/repair with fuel tank
EMPTY or with fuel shutoff valve OFF.

DO NOT

 tip engine or equipment at angle

which causes fuel to spill.
Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT
WITH FUEL IN TANK

Store  away  from  furnaces,  stoves,  water
heaters, clothes dryers, or other appliances
that have pilot light or other ignition source
because they could ignite fuel vapors.

WARNING

This  generator  does  not  meet  U.  S.  Coast
Guard Regulation 33CFR-183 and should not
be used on marine applications.


Failure  to  use  the  appropriate  U.  S.  Coast
Guard approved generator could result in
death  or  serious  injury  and/or  property
damage.

WARNING

Generator voltage could cause
electrical shock or burn resulting
in death or serious injury.

WARNING

S t a r t e r  c o r d  k i c k b a c k  ( r a p i d
retraction) will pull hand and arm
toward engine faster than you can
let  go  which  could  cause  broken
b o n e s ,  f r a c t u r e s ,  b r u i s e s ,  o r
sprains resulting in serious injury.

When starting engine, pull cord slowly until
resistance  is  felt  and  then  pull  rapidly  to
avoid kickback.


NEVER

 start or stop engine with electrical

devices plugged in and turned on.

WARNING

Fuel and its vapors are extremely flammable
and explosive which could cause burns, fire,
or explosion resulting in death or serious
injury and/or property damage.

WHEN ADDING OR DRAINING FUEL

Turn generator engine OFF and let it cool at
least 2 minutes before removing fuel cap.
Loosen cap slowly to relieve pressure in tank.
Fill or drain fuel tank outdoors.

DO NOT

 overfill tank. Allow space for fuel

expansion.

If fuel spills, wait until it evaporates before
starting engine.

Keep fuel away from sparks, open flames,
pilot lights, heat, and other ignition sources.

Check fuel lines, tank, cap, and fittings
frequently for cracks or leaks. Replace if
necessary.

DO NOT

 light a cigarette or smoke.


WHEN STARTING EQUIPMENT

Ensure spark plug, muffler, fuel cap, and air
cleaner are in place.

DO NOT

 crank engine with spark plug

removed.

Use approved transfer equipment, suitable
for the intended use, to prevent backfeed by
isolating generator from electric utility
workers.

English

             

Support: [email protected]

Summary of Contents for R-P03601

Page 1: ...ing equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage OWNER...

Page 2: ...f Contents Connecting to a Building s Electrical English Trouble Shooting 23 Parts Diagram and Parts List 24 Generator Parts Digram 24 Engine Parts Diagram 26 Parts List 27 Service Information 28 Warr...

Page 3: ...cts and how to avoid them This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended...

Page 4: ...duct downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizzy or weak while using this product shut it off and get to fresh air RIGHT AWAY See a doctor You may h...

Page 5: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Page 6: ...and and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury When starting engine pull cord slowly until resistance is f...

Page 7: ...loads OFF and disconnect from generator before stopping generator DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or we...

Page 8: ...n your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency NO...

Page 9: ...y Refer to the following instructions and pictures to remove the attached engine support brackets red under the engine 3 You may discard these brackets as they are no longer required for normal operat...

Page 10: ...l Cap 4 Choke Lever 5 Fuel Valve 6 Air Filter 7 208cc FIRMAN OHV Engine 8 Recoil Starter 9 10 Oil Filler Cap 11 Outlet Cover 12 Control Panel Bottle Opener We are always working to improve our product...

Page 11: ...rating NOTE 8 Outlet Cover Protect the receptacles from dust and debris 8 English A Digital display B AC voltage indicator C Frequency indicator D Hour indicator E Low oil indicator F Select button E...

Page 12: ...otive Gasoline Recoil 5 0 Gallon 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4550 FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section Spark Plug AN IMPOR...

Page 13: ...casionally to allow stator windings to heat and cool Adjusting the load will also cause engine speed to vary and help seat piston rings CAUTION H DRAIN PLUG L 5 Replace oil fill cap dipstick and fully...

Page 14: ...uel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or...

Page 15: ...erate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or childre...

Page 16: ...protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may...

Page 17: ...ablize WARNING When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 7 Pull the starter cord slowly until re...

Page 18: ...um wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle Do not apply heavy electrical load during break in period the first f...

Page 19: ...below LOW mark on dipstick 1 Add oil to bring level to HIGH mark 2 Restart engine and if the engine stops again a low oil condition may still exist DO NOT try to restart the engine 3 Contact an Author...

Page 20: ...ndations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjec...

Page 21: ...ain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a...

Page 22: ...ainer cup with gasoline c Tightly fasten the cup to main body making sure to avoid fuel leak SCREEN O ring CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and clean wi...

Page 23: ...rator Water can enter the generator through the cooling slots and damage the generator windings Use a damp cloth to clean exterior surfaces of the generator Use a soft bristle brush to remove dirt and...

Page 24: ...pour about one teaspoon of engine oil through the spark plug hole then pull the recoil starter several times to distribute the oil for lubricating the cylinder Reattach the spark plug Pull recoil slo...

Page 25: ...as lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner...

Page 26: ...Page 24 PARTS DIAGRAM AND PARTS LIST P03601 Parts Diagram English...

Page 27: ...Page 25 FIRMAN 208cc Engine Parts Diagram English...

Page 28: ...ator A Isolator B Grommet Screw M5 14 Control Box Nut M3 Nut M4 Multi Meter Control Panel Engine Switch Outlet Cover L5 30R Outlet Cover TT 30R Outlet Cover 5 20R Fig Bolt M5 16 Nut M5 Nut M5 Flat Was...

Page 29: ...5 336723586 336723587 336723588 336723589 336723590 336723591 336723592 336723593 336723594 336723595 336723596 336723597 336723598 336713532 336423500 336423501 336423502 336423503 336423504 33642350...

Page 30: ...your name and address and a description of the defect 3 Ship to the address provided by ARC 4 Write the RMA number provided on the outside of the package What Your Warranty Does Not Cover Improper ins...

Page 31: ...gine is Designed built and equipped so as to conform with all applicable regulations adopted by the Air Resources Board and US EPA and Free from defects in materials and workmanship that cause the fai...

Page 32: ...old Catalytic converter Muffler gasket pulse valve 4 Air induction system including Intake pipe manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evapor...