Firman R-P03601 Owner'S Manual Download Page 24

Page 22

English

            

DANGER

Long Term Storage

It is important to prevent gum deposits from forming
in essential fuel system parts such as the carburetor,
fuel  hoses  or  tank  during  storage.  Also,  experience
indicates  that  alcohol-blended  fuels  (called  gasohol,
ethanol or methanol) can attract moisture, which leads
to separation and formation of acids during storage.
Acidic gas can damage the fuel system of an engine
while in storage.
When the generator set is not being operated, or
is being stored for more than one month, follow
these instructions to avoid engine problems:
1-

ADD

 a properly formulated commercially 

FUEL

STABILIZER

 to the tank if it is not already added.

2-Operate the engine for 5-10 minutes to circulate
treated  fuel  into  fuel  lines  and  carburetor  before

3- After engine cools down, remove all gasoline
from the fuel tank. Use a commercially available,
non-conductive vacuum siphon.

shutdown.

Drain fuel into approved container outdoors,
away from open flame. Be sure engine is cool.
Do not smoke.

4-

FUEL STARVATION:

  Start and run the generator

until it stops  from lack of fuel. This will dry out all
remaining  fuel  in  tank,  fuel  lines  and  carburetor.

7-Remove spark plug and pour about one teaspoon
of engine oil through the spark plug hole, then pull
the recoil starter several times to distribute the oil for
lubricating  the  cylinder.  Reattach  the  spark  plug.
Pull  recoil  slowly  until  resistance  is  felt.  This  will
close  the  valves  so  moisture  cannot  enter  engine
cylinder. Gently release recoil starter.

5-Allow the unit to cool entirely before cleaning
and storage.

6-Change oil with recommended grade oil.

Any  damages  or  hazards  caused  by  using
improper  fuel,  improperly  stored  fuel,  and/
or improperly formulated stabilizers, are not
covered by manufacturer's warranty.

8-Keep the engine switch and fuel valve on “OFF”
position.
9-Cover the unit and store in a clean, dry place
out of direct sunlight. 

NEVER USE WATER TO

CLEAN GENERATOR.

NOTE:

We recommend always using a fuel stabilizer.

A FUEL STABLIZER

 will minimize the formula-

tion of fuel gum deposits during storage, the
fuel stabilizer can be added to the gasoline in
the fuel tank, or into the gasoline in a storage
container.

If  it  is  not  practical  to  empty  the  fuel  tank  and
the  unit  is  to  be  stored  for  some  time,  use  a
commercially available 

FUEL STABILIZER

 added

to the gasoline to increase the life of the gasoline.
Run  the  unit  for  5-10  minutes,  turn  off  the  fuel
valve  and  allow  to  run  until  engine  stops  from
lack of fuel (

FUEL STARVATION

).

Do not store gasoline from one season to
another season.

Summary of Contents for R-P03601

Page 1: ...ing equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage OWNER...

Page 2: ...f Contents Connecting to a Building s Electrical English Trouble Shooting 23 Parts Diagram and Parts List 24 Generator Parts Digram 24 Engine Parts Diagram 26 Parts List 27 Service Information 28 Warr...

Page 3: ...cts and how to avoid them This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended...

Page 4: ...duct downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizzy or weak while using this product shut it off and get to fresh air RIGHT AWAY See a doctor You may h...

Page 5: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Page 6: ...and and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury When starting engine pull cord slowly until resistance is f...

Page 7: ...loads OFF and disconnect from generator before stopping generator DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or we...

Page 8: ...n your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency NO...

Page 9: ...y Refer to the following instructions and pictures to remove the attached engine support brackets red under the engine 3 You may discard these brackets as they are no longer required for normal operat...

Page 10: ...l Cap 4 Choke Lever 5 Fuel Valve 6 Air Filter 7 208cc FIRMAN OHV Engine 8 Recoil Starter 9 10 Oil Filler Cap 11 Outlet Cover 12 Control Panel Bottle Opener We are always working to improve our product...

Page 11: ...rating NOTE 8 Outlet Cover Protect the receptacles from dust and debris 8 English A Digital display B AC voltage indicator C Frequency indicator D Hour indicator E Low oil indicator F Select button E...

Page 12: ...otive Gasoline Recoil 5 0 Gallon 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4550 FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section Spark Plug AN IMPOR...

Page 13: ...casionally to allow stator windings to heat and cool Adjusting the load will also cause engine speed to vary and help seat piston rings CAUTION H DRAIN PLUG L 5 Replace oil fill cap dipstick and fully...

Page 14: ...uel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or...

Page 15: ...erate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or childre...

Page 16: ...protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may...

Page 17: ...ablize WARNING When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 7 Pull the starter cord slowly until re...

Page 18: ...um wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle Do not apply heavy electrical load during break in period the first f...

Page 19: ...below LOW mark on dipstick 1 Add oil to bring level to HIGH mark 2 Restart engine and if the engine stops again a low oil condition may still exist DO NOT try to restart the engine 3 Contact an Author...

Page 20: ...ndations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjec...

Page 21: ...ain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a...

Page 22: ...ainer cup with gasoline c Tightly fasten the cup to main body making sure to avoid fuel leak SCREEN O ring CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and clean wi...

Page 23: ...rator Water can enter the generator through the cooling slots and damage the generator windings Use a damp cloth to clean exterior surfaces of the generator Use a soft bristle brush to remove dirt and...

Page 24: ...pour about one teaspoon of engine oil through the spark plug hole then pull the recoil starter several times to distribute the oil for lubricating the cylinder Reattach the spark plug Pull recoil slo...

Page 25: ...as lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner...

Page 26: ...Page 24 PARTS DIAGRAM AND PARTS LIST P03601 Parts Diagram English...

Page 27: ...Page 25 FIRMAN 208cc Engine Parts Diagram English...

Page 28: ...ator A Isolator B Grommet Screw M5 14 Control Box Nut M3 Nut M4 Multi Meter Control Panel Engine Switch Outlet Cover L5 30R Outlet Cover TT 30R Outlet Cover 5 20R Fig Bolt M5 16 Nut M5 Nut M5 Flat Was...

Page 29: ...5 336723586 336723587 336723588 336723589 336723590 336723591 336723592 336723593 336723594 336723595 336723596 336723597 336723598 336713532 336423500 336423501 336423502 336423503 336423504 33642350...

Page 30: ...your name and address and a description of the defect 3 Ship to the address provided by ARC 4 Write the RMA number provided on the outside of the package What Your Warranty Does Not Cover Improper ins...

Page 31: ...gine is Designed built and equipped so as to conform with all applicable regulations adopted by the Air Resources Board and US EPA and Free from defects in materials and workmanship that cause the fai...

Page 32: ...old Catalytic converter Muffler gasket pulse valve 4 Air induction system including Intake pipe manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evapor...

Reviews: