Page 21

Spark Plug Maintenance

Changing the spark plug will help your engine
to start easier and run better.
(a) Remove the spark plug cap.

(d) Adjust the electrode gap to 0.7 to 0.8 mm

(0.028” to 0.031”).

(e) Seat spark plug in position and thread by
hand to prevent cross threading.
(f) Tighten plug with provided wrench and put
the cap back on spark plug.

SPARK PLUG: TORCH F6RTC

NGK  BPR6ES
CHAMPION RN9YC equivalent.

Cleaning Fuel Strainer

Dirt and water in the fuel are removed by the fuel
strainer.

(a) Remove the strainer cup and throw away water
and dirt.

(b) Clean the screens and strainer cup with gasoline.

(c) Tightly fasten the cup to main body,
making sure to avoid fuel leak.

SCREEN 
O-ring

CUP

BODY

(b) Remove spark plug using provided wrench.

     Inspect spark plug for damage and clean
with a wire brush before reinstalling

Inspect

 

Muffler

 

and

 

Spark

 

Arrester

Inspect the muffler for cracks, corrosion, or
other damage. Remove the spark arrester, if
equipped, and inspect for damage or carbon
blockage. If replacement parts are required,
make sure to use only original equipment
replacement parts.

Exhaust heat/gases could ignite combustibles,
structures or damage fuel tank causing a fire,
resulting in death or serious injury and/or
property. Contact with muffler area could cause
burns resulting in serious injury.

WARNING

A

B

A- Spark plug
B- Spark plug cap

c)

English

             

Summary of Contents for R-P03501

Page 1: ...ting equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage OWNER S MANUAL PORTABLE GENERATOR REMANUFACTURED MODEL NUMBER R P03501 ARC LP NO Purchase Date ...

Page 2: ... Contents Connecting to a Building s Electrical English Trouble Shooting 24 Parts Diagram and Parts List 25 Generator Parts Diagram 25 Engine Parts Diagram 26 Parts List 27 Service Information 29 Warranty 29 22 ...

Page 3: ...ucts and how to avoid them This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended for any other purpose It is important that you read and understand these instructions thoroughly before attempting to start or operate this equipment Save these original instructions for future refer...

Page 4: ...oduct downwind and point the engine exhaust away from occupied spaces If you start to feel sick dizzy or weak while using this product shut it off and get to fresh air RIGHT AWAY See a doctor You may have carbon monoxide poisoning Avoid other generator hazards READ MANUAL BEFORE USE WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer bir...

Page 5: ...ide and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Basement Crawl Space Living Area Attic Entry Way Porch Mudroom English Support support arcaugusta com ...

Page 6: ...hand and arm toward engine faster than you can let go which could cause broken bones fractures bruises or sprains resulting in serious injury When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on WARNING Fuel and its vapors are extremely flammable and explosive which could c...

Page 7: ...l loads OFF and disconnect from generator before stopping generator DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generato...

Page 8: ...in your household depends on electrical equipment to live Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency NOTE Improper treatment of generator could damage it and shorten its life Axle Pin 2 8 0 in Wheel 2 Flat Washer 2 Cotter Pin 2 Support Leg with Vibration Mounts 1 Flange Bolt M8x16 for Support Leg 2 Fl...

Page 9: ... following instructions and pictures to remove the attached engine support brackets red under the engine 3 You may discard these brackets as they are no longer required for normal operation of your generator Your generator is now ready for use Refer to your owner s manual for proper oil fill and startup instructions Engine Support Brackets red color Remove these 4 nuts bolts as indicated Supplied ...

Page 10: ...o usage If problems arise when assembling the generator email support arcaugusta com Install the Wheel Kit F E G H K 1 Before adding wheels tip the generator on its side 2 Slide the axle pin A through the wheel B 3 Slide the axle pin A through the mount point on the frame and flat washer D 4 Secure the wheel and axle pin with the cotter pin C 5 Repeat steps 2 4 to attach another wheel 1 Attach the...

Page 11: ...er 5 Fuel Valve 6 Air Filter 7 208cc FIRMAN OHV Engine 8 Recoil Starter 9 Bottle Opener 10 8 0 Flat Free Wheel 11 Oil Filler Cap 12 Outlet Cover 13 Control Panel 14 Handle We are always working to improve our products Therefore the enclosed product may differ slightly from the image on this page English 1 2 ...

Page 12: ...7 6 120V 30A RV NEMA TT 30R Total power drawn from all receptacles must not exceed the name plate rating NOTE 8 Outlet Cover Protect the receptacles from dust and debris 8 A Digital display B AC voltage indicator C Frequency indicator D Hour indicator E Low oil indicator F Select button Engine Switch Flip the switch to the ON l position and pull the recoil starter to start the generator Turn to th...

Page 13: ...motive Gasoline Recoil 5 0 Gallon 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4450 FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section Spark Plug AN IMPORTANT MESSAGE ABOUT TEMPERATURE When operated above 77 F 25 C there may be a decrease in power Maximum wattage and current are subject to and limited by such factors as fuel BTU content ambient temper...

Page 14: ... the sensor will activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an even surface to correct this If engine fails to start the oil level may not be sufficient to deactivate low oil level switch Make sure the sump is completely full of oil H DRAIN PLUG L 5...

Page 15: ...fuel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or wipe up any spilled gasoline English CAUTION Slowly add unleaded gasoline to fuel tank Do not overfill tank Do not fill above the red line indicator This will allow expansion in hot weather and prev...

Page 16: ...DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator ConnectingtoaBuilding sElectricalSystem WARNING Generator voltage could cause electrical shock or burn resulting in death or serious injury The part number a...

Page 17: ... protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may impair the proper functioning of sensitive electronic equipment WARNING POISONOUS GAS HAZARD Do not block generator air vents with paper or other material CAUTION Tilting can cause fuel spillage CAUT...

Page 18: ...ition 9 Allow generator to run at no load for few minutes upon each initial start up to permit engine and generator to stablize WARNING When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 7 Pull the starter cord slowly until resistance is felt and then pull rapidly 3 Disconnect all electrical loads from t...

Page 19: ...gine speed adjusted at the factory for correct output Readjusting will void warranty CAUTION When applying a load do not exceed the maximum wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle Do not apply heavy electrical load during break in period the first five hours of operations WARNING Let the generator run at no loa...

Page 20: ... below LOW mark on dipstick 1 Add oil to bring level to HIGH mark 2 Restart engine and if the engine stops again a low oil condition may still exist DO NOT try to restart the engine 3 Contact an Authorized FIRMAN Service Dealer 4 DO NOT operate engine until oil level is corrected Overloading a generator in excess of its rated wattage capacity can result in damage to the generator and to connected ...

Page 21: ...endations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjected to operator abuse or negligence To receive full value from the warranty the operator must maintain the generator as instructed in this manual Some adjustments will need to be made periodically to...

Page 22: ...tain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a new engine change oil after 25 hours DRAIN PLUG Please use a container to dispose of the oil at an approved recycling center b Reinstall the drain plug and fill the engine with oil until it reaches t...

Page 23: ...rainer cup with gasoline c Tightly fasten the cup to main body making sure to avoid fuel leak SCREEN O ring CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and clean with a wire brush before reinstalling Inspect Muffler and Spark Arrester Inspect the muffler for cracks corrosion or other damage Remove the spark arrester if equipped and inspect for damage or carbon ...

Page 24: ...erator Water can enter the generator through the cooling slots and damage the generator windings Use a damp cloth to clean exterior surfaces of the generator Use a soft bristle brush to remove dirt and oil Use an air compressor 25 PSI to clear dirt and debris from the generator Inspect all air vents and cooling slots to ensure that they are clean and unobstructed Depending on the type fuel used th...

Page 25: ...d pour about one teaspoon of engine oil through the spark plug hole then pull the recoil starter several times to distribute the oil for lubricating the cylinder Reattach the spark plug Pull recoil slowly until resistance is felt This will close the valves so moisture cannot enter engine cylinder Gently release recoil starter 5 Allow the unit to cool entirely before cleaning and storage 6 Change o...

Page 26: ...has lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner 5 Fill fuel tank 6 Drain fuel tank and carburetor fill with fresh fuel 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh fuel 10 Wait 5 minutes and re ...

Page 27: ...Page 25 PARTS DIAGRAM AND PARTS LIST P03501 PARTS DIAGRAM English ...

Page 28: ...Page 26 English FIRMAN 208cc Engine Parts Diagram ...

Page 29: ...413502 336413503 336413508 336413509 Fuel Valve Guard Muff Frame Axle Pin Wheel Cotter Pin Rubber Support Nut M8 Bolt M8 16 Support Leg Bolt M6 25 IsolatorA Isolator B Grommet Screw M5 14 Control Box Nut M3 Nut M4 Screw washerAssy M4 8 Multi Meter Control Panel Engine Switch Outlet Cover L5 30R Outlet Cover TT 30R Outlet Cover 5 20R Flange Bolt M5 16 Nut M5 Nut M5 Flat Washer Grommet Sleeve Recept...

Page 30: ... 336723585 336723586 336723587 336723588 336723589 336723590 336723591 336723592 336723593 336723594 336723595 336723596 336723597 336723598 336713532 336423500 336423501 336423502 336423503 336423504 336423505 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 NO Part Number Descript...

Page 31: ... your name and address and a description of the defect 3 Ship to the address provided by ARC 4 Write the RMA number provided on the outside of the package What Your Warranty Does Not Cover Improper installation Failure of the product if it is abused misused or used for other than the intended purpose or used commercially Replacement of house fuses or resetting of circuit breakers Damage to the pro...

Page 32: ...ngine is Designed built and equipped so as to conform with all applicable regulations adopted by the Air Resources Board and US EPA and Free from defects in materials and workmanship that cause the failure of a warranted part to be identical in all material respects to the part as described in the engine manufacturers application for certification The warranty on emissions related parts is as foll...

Page 33: ...fold Catalytic converter Muffler gasket pulse valve 4 Air induction system including Intake pipe manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting clamps English Customer Service 1 844 FIRMAN1 Limitations This Emission Control Systems Warranty shall not...

Reviews: