ADD ENGINE OIL

Page 14

1.Place generator on a flat, level surface.

2.Clean area around oil fill and remove yellow
oil fill cap/dipstick.
3.Wipe dipstick clean.

NOTE:

The engine is equipped with a low oil shut-off and
will stop when the oil level in the crankcase falls
below the threshold level.

NOTE:

We consider the first 5 hours of run time to be
the break-in period for the unit. During the break
in period stay at or below 50% of the running
watt rating and vary the load occasionally to allow
stator windings to heat and cool. Adjusting the
load will also cause engine speed to vary and help
seat piston rings.

CAUTION

The unit is equipped with a low oil shutdown.If
the oil level becomes lower than required,the
sensor will activate a warning device or stop the
engine.
If generator shuts off and the oil level is within
specifications, check to see if generator is sitting
at an angle that forces oil to shift. Place on an
even surface to correct this. If engine  fails to
start, the oil level may not be sufficient to
deactivate low oil level switch. Make sure the
sump is completely full of oil.

(H)

DRAIN PLUG

(L)

5.Replace oil fill cap/dipstick and fully tighten.
6.Oil level should be checked prior to each use
or at least every 8 hours of operation

.

 Keep oil

level maintained.

4.Using oil funnel, slowly pour contents of
provided oil bottle into oil fill opening to the
"H" mark on dipstick. Be careful do not
overfill. Overfilling with oil could cause the
engine to not start or hard starting.

Low Oil Shutdown 

Degrees Celsiusº(Outside)

Full Synthetic 5W-30

Degrees Fahrenheitº(Outside)

5W-30

10W-40

10W-30

CAUTION

H

L

             

Summary of Contents for P03612

Page 1: ...operating equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverag...

Page 2: ...r Recoil Start 18 Starting the Generator Electric Start 19 Starting the Generator Remote Start 20 Connecting Electrical Loads 21 Stopping the Engine 21 Low Oil Shutdown 22 Do Not Overload Generator 22...

Page 3: ...ortant Safety Information The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit ar...

Page 4: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD WARNING WARNING...

Page 5: ...ning ONLY use outside and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window...

Page 6: ...hich could cause burns fire or explosion resulting in death or serious injury and or property damage WHEN ADDING OR DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before re...

Page 7: ...or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service gene...

Page 8: ...this product to power medical devices or medical appliances Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live Inform your electri...

Page 9: ...arranty Refer to the following instructions and pictures to remove the attached engine support brackets red under the engine 3 You may discard these brackets as it is no longer required for normal ope...

Page 10: ...The generator requires some assembly prior to usage Install the Wheel Kit H K 1 Before adding wheels tip the generator on its side 2 Slide the axle pin A through the wheel B 3 Slide the axle pin A thr...

Page 11: ...ive battery cable red boot is securely tightened to the positive battery post Make sure boot is over battery post 2 Remove bolt M5X10 and M5 nut from black cable ring 3 Remove vinyl cap from the negat...

Page 12: ...IRMAN OHV Engine 8 Recoil Starter 9 Bottle Opener 10 Remote Holder We are always working to improve our products Therefore the enclosed product may differ slightly from the image on this page 1 2 The...

Page 13: ...l receptacles must not exceed the name plate rating Engine Start Switch Used to start engine from the starter motor Electric start model only To start engine press and hold the switch in the START ll...

Page 14: ...Control Programming 1 Flip the engine switch to the RUN l position 2 Flip the battery switch to the ON l position 3 Push and hold the program button on the control panel for approximately 3 seconds T...

Page 15: ...o Unleaded Automotive Gasoline 5 0 Gallon 20 3 oz 0 6L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 4550 FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section AN IMPORTA...

Page 16: ...ired the sensor will activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to...

Page 17: ...ed fuel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engin...

Page 18: ...T operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or chi...

Page 19: ...and protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation...

Page 20: ...NG When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 8 Pull the starter cord slowly until resistance is...

Page 21: ...and fuel 3 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plugged in or turned on 4 Turn the fuel valve to the ON l position 5 Flip the en...

Page 22: ...READYTO STARTTHEGENERATOR If the remote control is replaced then you will need to go through programming procedure in Remote Control Programming section 3 Disconnect all electrical loads from the gene...

Page 23: ...ol panel is in on position This unit has been pretested and adjusted to handle its full capacity Before starting the generator disconnect all load Apply load only after generator is running Voltage is...

Page 24: ...lease see the Storage section for proper engine and fuel storage Low Oil Shutdown If the engine oil drops below a preset level an oil switch will stop the engine Check oil level with dipstick If oil l...

Page 25: ...attached devices follow these steps to add electrical load 1 Start the generator with no electrical load attached 2 Allow the engine to run for several minutes to stabilize 3 Plug in and turn on the...

Page 26: ...commendations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been s...

Page 27: ...in certain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hour...

Page 28: ...d strainer cup with gasoline c Tightly fasten the cup to main body making sure to avoid fuel leak SCREEN O ring CUP BODY b Remove spark plug using provided wrench Inspect spark plug for damage and cle...

Page 29: ...cloth to clean exterior surfaces of the generator Use a soft bristle brush to remove dirt and oil Use an air compressor 25 PSI to clear dirt and debris from the generator Inspect all air vents and co...

Page 30: ...parts such as the carburetor fuel hoses or tank during storage Also experience indicates that alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation a...

Page 31: ...lizer A FUEL STABLIZER will minimize the formula tion of fuel gum deposits during storage the fuel stabilizer can be added to the gasoline in the fuel tank or into the gasoline in a storage container...

Page 32: ...l tank 6 Drain fuel tank and carburetor fill with fresh fuel 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh fuel 10 Wait 5 minutes and re crank engin...

Page 33: ...Page 30 PARTS DIAGRAM AND PART LIST P03612 PARTS DIAGRAM...

Page 34: ...Page 31 208cc ENGINE PARTS DIAGRAM...

Page 35: ...play Fuel Filter Wire Mesh Fuel Cap Hose Fuel Fuel Valve Guard Muff Frame Axle Pin Wheel Cotter Pin Rubber Support Nut M8 Flange Bolt M8 16 61 62 63 64 65 66 68 69 71 72 73 74 75 76 77 78 79 80 81 82...

Page 36: ...Carburetor Gasket Air Cleaner Nut M6 Elbow Air Cleaner Clapboard Cover Subassembly Cylinder Head Gasket Cylinder Head Cover Plate Subassembly Lifter Stopper Head Subassembly Cylinder NO Part Number De...

Reviews: