FEATURES AND CONTROLS

1- Fuel Gauge

2- 1.7 Gallon(6.4L) Capacity Fuel Tank

3- Fuel Cap

4- Choke Lever

5- Fuel Valve

6- Air Filter 

7- 80cc FIRMAN OHV Engine

8- Recoil Starter

9- Oil Filler Cap

10- Outlet Cover

11- Control Panel

12- Data Decal / Serial Number

2

Summary of Contents for P01204

Page 1: ...P N 312745500 Rev 00 OPERATOR S MANUAL GASOLINE PORTABLE GENERATOR Record product information to reference when ordering parts or obtaining warranty coverage MODEL NUMBER P01204...

Page 2: ...pport This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for suppl...

Page 3: ...s vapors are extremely flammable which could cause burns or fire resulting in death or serious injury Engine exhaust could cause fire resulting in death or serious injury Hot Surface Muffler could cau...

Page 4: ...may be Federal or State regulations local codes or ordinances that apply to the intended use of the generator Consult a qualified electrician electrical inspector or the local agency having jurisdict...

Page 5: ...ing through any openings If an extension cord running directly into your home is used to power indoor items the operator recognizes that this increases the risk of CO poisoning to people inside the ho...

Page 6: ...d product may differ slightly from the image on this page 05 FEATURES AND CONTROLS 1 Fuel Gauge 2 1 7 Gallon 6 4L Capacity Fuel Tank 3 Fuel Cap 4 Choke Lever 5 Fuel Valve 6 Air Filter 7 80cc FIRMAN OH...

Page 7: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS...

Page 8: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS...

Page 9: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS...

Page 10: ...grounding requirements 5 Outlet Cover Protects the receptacles from dust and debris 3 Circuit Breakers The receptacles are protected by AC circuit protectors If the generator is overloaded or an exter...

Page 11: ...crawlspaces sheds or other partially enclosed spaces even if using fans or opening doors and windows for ventilation Carbon monoxide can quickly build up in these spaces and can linger for hours even...

Page 12: ...able generator at least 5 ft 1 5 m from any structure trees or vegetation over 12 in 30 cm in height Select an outdoor site that is dry and protected from the weather Do not move portable generator in...

Page 13: ...art to select the proper oil for the outdoor temperature range expected NOTICE Do not attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oi...

Page 14: ...enough to deactivate the internal low oil level switch Make sure the sump is completely full of oil to the upper limit H Do not operate engine until oil level issue is corrected Contact Firman custom...

Page 15: ...native main jet and installation instructions can be obtained by contacting Customer Support NOTICE Operation using an alternative main jet at elevations lower than the recommended minimum altitude ca...

Page 16: ...fuel cap and air cleaner are all in place 2 Move portable generator outdoors to safe operating location at least 20 feet from any occupied spaces 15 OPERATION 3 Disconnect all electrical loads from th...

Page 17: ...ectrical devices NOTICE If engine starts but fails to run or if portable generator shuts down during operation check oil level See Low Oil Shutdown section for more information 7 Pull the starter cord...

Page 18: ...ircuit breaker on control panel is in the closed on position 2 Start the generator with no electrical load attached 3 Allow the engine to run for several minutes to stabilize 4 Plug in and turn on the...

Page 19: ...e FIRMAN authorized service dealer Yellow light will blink for five seconds at the startup of generator to show CO ALERT is functioning properly TM Carbon monoxide accumulated around generator Prior t...

Page 20: ...stop the engine by moving the choke to the start position Let the generator run at no load for one minute to stabilize internal temperatures of the engine and generator 19 OPERATION 2 Flip the engine...

Page 21: ...he spark plug and replace the air filter New spark plug and clean air filter assure proper fuel air mixture and help your engine run at peak performance and last longer To be performed by knowledgable...

Page 22: ...rolonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REA...

Page 23: ...loth b Saturate foam air filter element with clean engine oil and squeeze in a clean cloth to remove excess oil Spark Plug Maintenance Changing the spark plug will help your engine start easier and ru...

Page 24: ...Arrester WARNING Contact with muffler area could cause burns resulting in serious injury Do not touch hot parts It is a violation of California Public Resource Code Section 4442 to use or operate the...

Page 25: ...ffler and attach with the screws NOTICE Failure to clean or replace spark arrester may result in decreased engine performance GENERATOR MAINTENANCE Make certain that the portable generator is kept cle...

Page 26: ...wn 3 There is no need to drain gasoline from the generator fuel tank if fuel stabilizer is added 4 FUEL STARVATION If you elect to drain fuel tank move generator outdoors Once fuel tank is drained tur...

Page 27: ...on level surface 3 Clean or replace air cleaner 4 Fill fuel tank with gasoline 5 Drain fuel tank and carburetor fill with fresh gasoline 6 Connect wire to spark plug 7 Replace spark plug 8 Drain gas...

Page 28: ...l Magneto Unleaded Automotive Gasoline 1 7 U S Gallons 6 4L 12 9 oz 0 38L Counter Clockwise Facing P T O Float Brushless Polyurethane Type Yes 1500 FIRMAN Rated Fequency 60Hz Oil Type See Add Engine O...

Page 29: ...PARTS DIAGRAM AND PART LIST P01204 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 28...

Page 30: ...80cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 29...

Page 31: ...M8x175 Ground Wire Bolt M6x90 Generator End Cover Cap Flange Bolt M5 12 Muffler Gasket Flat Washer 8 Lock Washer 8 Nut M8 Bolt M6x12 Bracket Muff Muffler Assembly Arrester Spark Bolt M6x12 Holder Spar...

Page 32: ...cting Rod Cap Connecting Rod Body Piston Pin Piston Pin Circlip Exhaust Valve Third Piston Ring Second Piston Ring First Piston Ring Piston Rings Set Outlke Bolt 5 1 1 10 1 1 1 1 1 1 1 2 2 4 2 1 1 1 2...

Page 33: ...English Customer Service 1 844 FIRMAN1 32 Parts Diagrams Parts Lists Wiring Diagram Wiring Diagram...

Page 34: ...ercial industrial use Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser This warranty only applies to the original...

Page 35: ...ontact Information You may contact FIRMAN at Address Firman Power Equipment Inc Attn Customer Service 8644 W Ludlow Dr www firmanpowerequipment com Peoria AZ 85381 We are FIRMAN POWER And we are here...

Page 36: ...a failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part o...

Page 37: ...manifold Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting cla...

Page 38: ...0 All rights reserved Any reprinting or unauthorized use without the written permission is expressly prohibited TM FIRMAN POWER EQUIPMENT INC 8644 W LUDLOW DR WWW FIRMANPOWEREQUIPMENT COM PEORIA AZ 85...

Reviews: