FEATURES AND CONTROLS
Control Panel
NOTICE
Total power drawn from all receptacles must not exceed the Data Decal rating.
2.
120V, 20A Duplex
- NEMA 5-20R (Not GFCI protected)
A maximum of 20 Amps current may be drawn from this duplex receptacle.
1.
Engine Switch
– Engine Switch – Flip the switch to the “ON”(l) position and pull the recoil starter to start
the generator. Turn to the “OFF”(O) position to turn off the generator.
4.
Ground Terminal
– Consult an electrician or authority having jurisdiction for local grounding
requirements.
5.
Outlet Cover -
Protects
the
receptacles from dust and debris.
3.
Circuit Breakers
– The receptacles are protected by AC circuit protectors. If the generator is
overloaded or an external short circuit occurs, a circuit protector may trip. If tripping occurs,
disconnect all electrical loads and determine the cause before attempting to continue using the
generator. Reset any tripped circuit protectors.
If multiple receptacles are used at the same time, the total current must be kept with-in the
portable generator Data Decal rating.
6.
CO Alert™ Carbon Monoxide (CO) Shutdown Indicator Light
— Indicates the engine shutdown due
to carbon monoxide accumulation around the generator or a CO Alert system fault occurred.
1
2
3
4
5
6
Summary of Contents for P01204
Page 7: ...English Customer Service 1 844 FIRMAN1 06 FEATURES AND CONTROLS...
Page 8: ...English Customer Service 1 844 FIRMAN1 07 FEATURES AND CONTROLS...
Page 9: ...English Customer Service 1 844 FIRMAN1 08 FEATURES AND CONTROLS...
Page 29: ...PARTS DIAGRAM AND PART LIST P01204 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 28...
Page 30: ...80cc ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 29...