2. Press the engine switch to the “
OFF
”(
O
) position.
A DC circuit protector has been provided to
protect the circuit from overloads. If an overload
occurs, the circuit protector will trip. The circuit
protector may be reset by pushing the button of
the protector.
DC CIRCUIT PROTECTOR
Charging a large capacity battery or a totally
discharged battery may cause the DC breaker to
turn off. In these cases, a separate battery charger
unit connected to an AC power source is
recommended instead of the DC receptacle on
the generator.
Stopping the Engine
Let the generator run at no-load for two
minutes to stabilize internal temperatures
of the engine and generator.
1. Turn off and remove entire electrical loads.
Never start or stop the generator with
electrical devices plugged in or turned on.
WARNING
Fuel and its vapors are extremely flammable and
explosive which could cause burns, fire or
explosion resulting in death, serious injury
and/or property damage.
DO NOT stop engine by moving choke control
to “
START
” position.
Important
: Always ensure that the Fuel Valve
and the Engine Switch are in the “OFF” position
when the engine is not in use.
If the engine will not be used for a period of two
weeks or longer, please see the Storage section
for proper engine and fuel storage.
2. Plug the battery charging cable into the DC
receptacle of the generator.
3. Connect the red (+) battery charger lead to the
red (+) battery terminal.
4. Connect the black (–) battery charger lead to
the black (–) battery terminal.
5. Start the generator.
NOTE:
When the battery circuit is in use the AC capacity
is reduced by 100 watts. Make sure the combined
load is within the rated limits.
WARNING
Do not continue to charge a battery that becomes
hot or is fully charged.
If a cover is used, do not install until unit has cooled.
3. Turn the fuel valve to the “
OFF
”(
O
) position.
Do not leave the generator until it has
completely stopped.
English Customer Service: 1-844-FIRMAN1
17
Do not expose to rain.
Charge only 12v lead-acid batteries. Other types
of batteries may burst causing personal injury
and damage.
Risk of explosive gas mixture. Read instructions
in owner’s guide before using charger.
Summary of Contents for P01202
Page 2: ......
Page 28: ...PARTS DIAGRAM AND PARTS LIST P01202 Parts Diagram English Customer Service 1 844 FIRMAN1 25 ...
Page 29: ...English Customer Service 1 844 FIRMAN1 26 152F 80cc Engine Parts Diagram ...
Page 38: ......
Page 65: ...26 Spanish Servicio al Cliente 1 844 FIRMAN1 152F 80cc Diagrama De Las Piezas ...
Page 74: ......
Page 101: ...26 152F 80cc Moteur Schéma Des Pièces Français Service Clients 1 844 FIRMAN1 ...