Firman P01001 Owner'S Manual Download Page 26

TROUBLE SHOOTING

Problem

Cause

Correction

Engine

 

is

 

running

but

 

no

 

AC

 

output

 

is

 

available

.

1. Circuit

 

breaker

 

is

 

open

.

2. Fault

 

in

 

generator

.

3. Poor

 

connection

 

or

 

defective

 

cord

set

.

4. Connected

 

device

 

is

 

bad

.

1. Reset

 

circuit

 

breaker

.

2. Contact

 

authorized

 

service

 

facility

.

3. Check

 

and

 

repair

.

4. Connect

 

another

 

device

 

that

 

is

 

in

good

 

condition

.

Engine

 

runs

 

good

 

at

 

no

-

load

 

but

 “

bogs

 

down

” 

when

 

loads

 

are

 

connected

.

1. Short

 

circuit

 

in

 

a

 

connected

 

load

.

2. Engine

 

speed

 

is

 

too

 

slow

.

3. Generator

 

is

 

overloaded

.

4. Shorted

 

generator

 

circuit

.

1. Disconnect

 

shorted

 

electrical

 

load

.

2. Contact

 

authorized

 

service

 

facility

.

3.  See

 

Don't Overload

 

Generator

4. Contact

 

authorized

 

service

 

facility

.

Engine

 

will

 

not

 

start

starts

 

and

 

runs

 

rough

 

or

 

shuts

 

down

 

when

 

running

.

1. Engine

 

switch

 

set

 

to

 

OFF

 (

O

)

position

.

2

.

Fuel

 

shutoff

 

lever

 

is

 

in

 

OFF

 (

O

)

position

.

3. Low

 

oil

 

level

.

4. Dirty

 

air

 

cleaner

.

5. Out

 

of

 

fuel

.

6. Stale

 

fuel

.

7.

 

Spark

 

plug

 

wire

 

not

 

connected

 

to

spark

 

plug

.

8. Bad

 

spark

 

plug

.

9. Water

 

in

 

fuel

.

 

10. Flooded

.

11. Excessively

 

rich

 

fuel

 

mixture

.

12. Intake

 

valve

 

stuck

 

open

 

or

 

closed

.

13. Engine

 

has

 

lost

 

compression

.

1. Set

 

engine

 

switch

 

to

 

ON

 (

l

)

position

.

2. Move

 

fuel

 

shutoff

 

lever

 

to

 

ON

 (

l

)

position

.

3. Fill

 

crankcase

 

to

 

proper

 

level

 

or

place

 

generator

 

on

 

level

 

surface

.

4. Clean

 

or

 

replace

 

air

 

cleaner

.

5. Fill

 

fuel

 

tank

.

6. 

 

Drain

 

fuel

 

tank

 

and

 

carburetor

fill

with

 

fresh

 

fuel

.

7. Connect

 

wire

 

to

 

spark

 

plug

.

8. Replace

 

spark

 

plug

.

9.

 

Drain

 

gas

 

tank

 

and

 

carburetor

fill

with

 

fresh

 

fuel

.

10

Wait

 5 

minutes

 

and

 

re

-

crank

 

engine

.

11. Contact

 

authorized

 

service

 

facility

.

12. Contact

 

authorized

 

service

 

facility

.

13. Contact

 

authorized

 

service

 

facility

.

Engine

 

lacks

 

power

.

1. Load

 

is

 

too

 

high

.

2. Dirty

 

air

 

filter

.

1. Don't

 

Overload

 

Generator

2. Replace

 

air

 

filter

.

Engine

hunts

or

 

falters

.

1. Carburetor

 

is

 

running

 

too

 

rich

 

or

 

too lean

.

1. Contact

 

authorized

 

service

 

facility

.

14. Clogged or dirty fuel filter.

5. Clean or replace fuel filter.

14. Clean or replace fuel filter.

3. Clogged or dirty fuel filter.
4. Clogged spark arrester.

3. Clean or replace fuel filter.
4. Clean or replace spark arrester.

2. Clogged or dirty fuel filter.

2. Clean or replace fuel filter.

Engine shuts down when 
running.

1. Out of fuel.
2. Dirty air cleaner.
3. Low oil level.

1. Fill fuel tank.
2. Clean or replace air cleaner.
3. Fill crankcase to proper level or place. 
generator on level surface.

5. Clogged or dirty fuel filter.

Summary of Contents for P01001

Page 1: ...operating equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverag...

Page 2: ...ectrical Loads 16 12V DC Outlet Battery Charger 16 Stopping the Engine 17 Low Oil Shutdown 18 Do Not Overload Generator 18 Maintenance And Storage 19 Maintenance Schedule 19 Engine Maintenance 20 Chan...

Page 3: ...e that the procedure work method or operating technique that you choose does not render the generator unsafe DANGER WARNING CAUTION DANGER indicates a potentially hazardous situation which if not avoi...

Page 4: ...SAFETY PRECAUTIONS WARNING POISONOUS GAS HAZARD WARNING WARNING...

Page 5: ...ONLY use outside and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or v...

Page 6: ...could cause burns fire or explosion resulting in death or serious injury and or property damage WHEN ADDING OR DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before removi...

Page 7: ...et weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generato...

Page 8: ...roduct to power life support devices or life support appliances NEVER use this product to power medical devices or medical appliances Inform your electricity provider immediately if you or anyone in y...

Page 9: ...e A B C D 1 Secure the handle to the fuel tank using the two handle bolts B M6X30 and rubber washers C 2 Use the supplied screwdriver to fasten securely DO NOT over tighten the bolts 3 Place the plug...

Page 10: ...Therefore the enclosed product may differ slightly from the image on this page 1 Fuel Gauge 2 1 3 Gallon Capacity Fuel Tank 3 Handle 4 Fuel Cap 5 Choke Lever 6 Fuel Valve 7 Air Filter 8 80cc FIRMAN O...

Page 11: ...cle 8 Outlet Cover Protect the receptacles from dust and debris 12V DC outlet 8 3 Amp of DC current may be drawn from the receptacle Use this outlet to charge 12V automotive type batteries ONLY See 12...

Page 12: ...tage Phase Power Factor Voltage regulator Alternator Type Running Watts Starting Watts Engine Engine Type Displacement Low Oil Shutdown Ignition System Starting System Fuel Capacity Fuel Tank Lubricat...

Page 13: ...the sensor will activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shif...

Page 14: ...uel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or...

Page 15: ...erate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or childre...

Page 16: ...protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may...

Page 17: ...blize WARNING When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 7 Pull the starter cord slowly until res...

Page 18: ...vehicle battery ground cable from the negative battery terminal Storage batteries give off EXPLOSIVE hydrogen gas while charging Do not allow smoking open flames sparks or spark producing equipment in...

Page 19: ...age DO NOT stop engine by moving choke control to START position Important Always ensure that the Fuel Valve and the Engine Switch are in the OFF position when the engine is not in use If the engine w...

Page 20: ...Contact an Authorized FIRMAN Service Dealer 4 DO NOT operate engine until oil level is corrected Do Not Overload Generator Overloading a generator in excess of its rated wattage capacity can result in...

Page 21: ...ndations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjec...

Page 22: ...aboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a new e...

Page 23: ...EEN BODY b Remove spark plug using provided wrench c Inspect spark plug for damage and clean with a wire brush before reinstalling Inspect Muffler and Spark Arrester Inspect the muffler for cracks cor...

Page 24: ...urface in a clean dry operating environment DO NOT expose the unit to extreme conditions excessive dust dirt moisture or corrosive vapours DO NOT use a garden hose to clean the generator Water can ent...

Page 25: ...ull recoil slowly until resistance is felt This will close the valves so moisture cannot enter engine cylinder Gently release recoil starter 5 Allow the unit to cool entirely before cleaning and stora...

Page 26: ...as lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner...

Page 27: ...PARTS DIAGRAM AND PARTS LIST P01001 Parts Diagram...

Page 28: ...152F 80cc Engine Parts Diagram...

Page 29: ...1 310715036 310725014 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 NO Part Number Description Qty 1 1 1 1 1 1 1 3 2 2 1 1 1 1 1 1 1 1 Bolt M4x16 Nut M4 Flat Washer 4 Lock Washer 6 Flat Washer...

Page 30: ...2 1 2 1 1 1 1 1 1 2 2 1 1 1 1 1 6 1 1 2 2 2 1 1 1 2 1 1 1 1 1 1 1 Connecting Rod Screw M6 25 312723552 312723553 312723554 312723555 312723556 312723557 312723558 312723559 312723560 312723561 3127235...

Reviews: