Firman P01001 Owner'S Manual Download Page 24

   

DO

 

NOT

 

touch

 

hot

 

parts

 

and

 

AVOID

 

hot

 

exhaust

 

   gases

.

   Allow

 

equipment

 

to

 

cool

 

before

 

touching

.

 
 

   

Keep at least 5 feet (1.5 m) of clearance on all

   sides of generator including overhead.

   Replacement parts must be the same and
   installed in the same position as the original

parts.

Clean

 

or

 

replace

 

spark

 

arrester

 

as

 

follows

:

1. Allow the engine to cool completely before

servicing the spark arrester.

2. Remove the screws securing the spark arrester

in place and then remove it from muffler.

3. Carefully remove the carbon deposits from

the spark arrester screen with a wire brush.

Failure to clean the spark arrester will result in
degraded engine performance.

GENERATOR MAINTENANCE

Make certain that the generator is kept clean
and stored properly. Only operate the unit on
a flat, level surface in a clean, dry operating
environment. 

DO NOT

 expose the unit to

extreme conditions, excessive dust, dirt,
moisture or corrosive vapours.

DO NOT

 use a garden hose to clean the generator.

Water can enter the generator through the cooling
slots and damage the generator windings.

Use a damp cloth to clean exterior surfaces of
the generator.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and
debris from the generator.
Inspect all air vents and cooling slots to ensure
that they are clean and unobstructed.

Depending on the type fuel used ,the type and
amount of lubricant used, and/or your operating
conditions, the exhaust part and muffler may
become blocked with carbon deposits. If you
notice power loss, you may need to remove these
deposits to restore performance.

CAUTION

CAUTION

4. Replace the spark arrester if it is damaged.
5. Position the spark arrester in the muffler and

tight it  with the screws.

Spark 

Arrester 

Screen

Screw

Summary of Contents for P01001

Page 1: ...operating equipment Ensure engine is stopped and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverag...

Page 2: ...ectrical Loads 16 12V DC Outlet Battery Charger 16 Stopping the Engine 17 Low Oil Shutdown 18 Do Not Overload Generator 18 Maintenance And Storage 19 Maintenance Schedule 19 Engine Maintenance 20 Chan...

Page 3: ...e that the procedure work method or operating technique that you choose does not render the generator unsafe DANGER WARNING CAUTION DANGER indicates a potentially hazardous situation which if not avoi...

Page 4: ...SAFETY PRECAUTIONS WARNING POISONOUS GAS HAZARD WARNING WARNING...

Page 5: ...ONLY use outside and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or v...

Page 6: ...could cause burns fire or explosion resulting in death or serious injury and or property damage WHEN ADDING OR DRAINING FUEL Turn generator engine OFF and let it cool at least 2 minutes before removi...

Page 7: ...et weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generato...

Page 8: ...roduct to power life support devices or life support appliances NEVER use this product to power medical devices or medical appliances Inform your electricity provider immediately if you or anyone in y...

Page 9: ...e A B C D 1 Secure the handle to the fuel tank using the two handle bolts B M6X30 and rubber washers C 2 Use the supplied screwdriver to fasten securely DO NOT over tighten the bolts 3 Place the plug...

Page 10: ...Therefore the enclosed product may differ slightly from the image on this page 1 Fuel Gauge 2 1 3 Gallon Capacity Fuel Tank 3 Handle 4 Fuel Cap 5 Choke Lever 6 Fuel Valve 7 Air Filter 8 80cc FIRMAN O...

Page 11: ...cle 8 Outlet Cover Protect the receptacles from dust and debris 12V DC outlet 8 3 Amp of DC current may be drawn from the receptacle Use this outlet to charge 12V automotive type batteries ONLY See 12...

Page 12: ...tage Phase Power Factor Voltage regulator Alternator Type Running Watts Starting Watts Engine Engine Type Displacement Low Oil Shutdown Ignition System Starting System Fuel Capacity Fuel Tank Lubricat...

Page 13: ...the sensor will activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shif...

Page 14: ...uel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let any spilled fuel evaporate before starting engine or...

Page 15: ...erate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or childre...

Page 16: ...protected from the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may...

Page 17: ...blize WARNING When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback 4 Turn the fuel valve to the ON l position 7 Pull the starter cord slowly until res...

Page 18: ...vehicle battery ground cable from the negative battery terminal Storage batteries give off EXPLOSIVE hydrogen gas while charging Do not allow smoking open flames sparks or spark producing equipment in...

Page 19: ...age DO NOT stop engine by moving choke control to START position Important Always ensure that the Fuel Valve and the Engine Switch are in the OFF position when the engine is not in use If the engine w...

Page 20: ...Contact an Authorized FIRMAN Service Dealer 4 DO NOT operate engine until oil level is corrected Do Not Overload Generator Overloading a generator in excess of its rated wattage capacity can result in...

Page 21: ...ndations Regular maintenance will improve the performance and extend the life of the generator See any authorized dealer for service The generator s warranty does not cover items that have been subjec...

Page 22: ...aboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine oil every 100 hours for a new e...

Page 23: ...EEN BODY b Remove spark plug using provided wrench c Inspect spark plug for damage and clean with a wire brush before reinstalling Inspect Muffler and Spark Arrester Inspect the muffler for cracks cor...

Page 24: ...urface in a clean dry operating environment DO NOT expose the unit to extreme conditions excessive dust dirt moisture or corrosive vapours DO NOT use a garden hose to clean the generator Water can ent...

Page 25: ...ull recoil slowly until resistance is felt This will close the valves so moisture cannot enter engine cylinder Gently release recoil starter 5 Allow the unit to cool entirely before cleaning and stora...

Page 26: ...as lost compression 1 Set engine switch to ON l position 2 Move fuel shutoff lever to ON l position 3 Fill crankcase to proper level or place generator on level surface 4 Clean or replace air cleaner...

Page 27: ...PARTS DIAGRAM AND PARTS LIST P01001 Parts Diagram...

Page 28: ...152F 80cc Engine Parts Diagram...

Page 29: ...1 310715036 310725014 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 NO Part Number Description Qty 1 1 1 1 1 1 1 3 2 2 1 1 1 1 1 1 1 1 Bolt M4x16 Nut M4 Flat Washer 4 Lock Washer 6 Flat Washer...

Page 30: ...2 1 2 1 1 1 1 1 1 2 2 1 1 1 1 1 6 1 1 2 2 2 1 1 1 2 1 1 1 1 1 1 1 Connecting Rod Screw M6 25 312723552 312723553 312723554 312723555 312723556 312723557 312723558 312723559 312723560 312723561 3127235...

Reviews: