12
OPERATION
ZERO E 2000
AC Charging Cable
Generator
NOTICE
If the AC Outlet is overloaded or a short circuit occurs, the Portable Power Station circuit
breaker may trip. When the source of overload or short circuit is cleared, press the circuit breaker
to reset.
Solar Charging
The Portable Power Station supports 11-50V DC input voltage, exceeding 50V could cause damage
to the Portable Power Station. Do not use solar panels with voltage higher than 50 volts.
1. Connect the Female EC5 connector of the provided EC5-MC4 Cable to the Male EC5 connector
on the Portable Power Station.
2. Then connect the EC5 to MC4 Cable to the solar panels with MC4 connector.
Series Configurations for PV Solar Panels
WARNING! Shock hazard do not connect or disconnect the solar panels when they are open, make
sure all solar panels are closed before wiring them in series.
The following are the schematic diagrams showing the use of 2 and 3 solar panels in series. Before
connecting an solar panels to the Portable Power Station verify that the total number of solar
panels connected in series does not exceed 50V.
1. Connect the solar panels MC4 connectors in series.
2. Connect the Female EC5 connector of the provided EC5-MC4 Cable to the Male EC5 connector
on the Portable Power Station.
NOTICE
ZERO E
Solar Charging Cable
(EC5-MC4 Cable)
Solar Panel with
MC4 Connector
English Customer Service: 1-844-FIRMAN1