DESCRIPTION

The EC485 converter is an accessory for both the Fireye

®

 FLAME-MONITOR™ flame safeguard

control system and the 45FS1 and 45UVFS1 Flame 

Signature Scanner

™ controls. The EC485 is an

RS232 to RS485 converter used to perform the following functions:

1.

Customize the operating control messages and lockout alarm messages of the E300 Expansion
Module. 

2.

Interface between an IBM compatible PC running the FS700 Communication Software and the
45FS1 and 45UVFS1 Flame 

Signature Scanner

 to provide remote communications capability.

3.

Interface between an IBM compatible PC running the E720 Communication Software and the
E340 Burner Management Control System to provide remote communications capability.

The EC485 provides the means to directly connect to any device that has RS485 communication
capability.

The EC485 is packaged with an RJ12 telephone jack mounted on a PC board to provide an easy
method to use the ED512 cables to interface to the EP programmers when customizing E300 mes-
sages.

The EC485 also includes a 120 VAC to 12 VDC power supply.

RS-485 Driver Control, RTS / SD Jumper:

The RS-485 side of the converter must be enabled to transmit data, and disabled when not transmit-
ting.  Via a jumper on the converter, either 

“RTS”

 or 

“SD”

 is selected as the control means to auto-

matically enable and disable the converter.

With 

SD

 (Send Data) control selected, circuitry within the converter automatically controls the

transmitter by sensing the data on the RS-232 side. This circuitry enables the driver during data
transmission and disables the driver after the last character has been sent.

With 

RTS

 (Request To Send) control selected, the external software controls the driver by raising

and lowering the Request To Send line on the RS-232 side. Because the RTS timing is not precisely
controlled, this method is not usually suitable for Windows based systems.

EC485

RS232/RS485

CONVERTER

EC-4851

February 6, 2017

Summary of Contents for EC485

Page 1: ...ack mounted on a PC board to provide an easy method to use the ED512 cables to interface to the EP programmers when customizing E300 mes sages The EC485 also includes a 120 VAC to 12 VDC power supply RS 485 Driver Control RTS SD Jumper The RS 485 side of the converter must be enabled to transmit data and disabled when not transmit ting Via a jumper on the converter either RTS or SD is selected as ...

Page 2: ... CABLE CONNECTIONS DB25 to DB9 2 Connect the ED612 RJ12 female connector provided with the EC485 to terminals TD A TD B RD A and RD B on the EC485 The pins on the ED610 will line up with the terminals on the EC485 converter 3 Set the jumpers on the EC485 converter to SD and ECHO OFF See diagram below 4 Plug on end of the ED512 2 4 8 cable into the RJ12 jack on the ED612 and the other end into eith...

Page 3: ...in wiring configuration The Fireye communication software program P N E720W is required for communication with the E340 controls Fireye recommends using the E500 Communication interface when communicating with the E340 controls since the E500 provides communication with the Flame Monitor flame safeguard con trols as well However the EC485 converter can be used to communicate only with the E340 con...

Page 4: ...YE MAKES NO WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY EXPRESS OR IMPLIED Except as specifically stated in these general terms and conditions of sale remedies with respect to any product or part number manufactured or sold by Fireye shall be limited exclusively to the right to replacement or repair as above provided In no event shall Fireye be liable for consequential or special damages of ...

Reviews: