WHAT TO DO IN CASE OF A FIRE 

1. Don’t panic; stay calm.
2. Leave the building as quickly as possible. Touch doors to feel

if they are hot before opening them. Use an alternate exit if

necessary. Crawl along the floor, and DO NOT stop to collect

anything. 

3. Meet at a pre-arranged meeting place outside the building. 
4. Call the fire brigade (Dial 999) from OUTSIDE the building.
5. DO NOT GO BACK INSIDE A BURNING BUILDING. Wait for 

the fire brigade to arrive. 

These guidelines will assist you in the event of a fire. However, to
reduce the chance that fires will start, practice fire safety rules and
prevent hazardous situations

TROUBLESHOOTING 

DANGER:

Always turn off power at main fuse box or 

consumer unit before taking trouble-shooting

action.

WARNING:

DO NOT disconnect battery or mains power

to quiet an unwanted alarm. This will remove

your protection. Fan the air or open a win-

dow to remove smoke or dust. For Models

KF10, KF10LL, KF10R, KF20, KF20LL and

KF20R you may also use the Hush Button

feature to quiet unwanted alarms.

7

!

!

PROBLEM

SOLUTION

Smoke alarm does not
sound when tested.

NOTE: Push and hold
test button for at least
five (5) seconds while
testing!

1. Check that AC power is

turned on. Green LED
should be illuminated.

2. Turn off power. Remove

smoke alarm from mount-
ing plate and:

a. check that connector plug

is securely attached.

b. check that battery is

properly attached to con-
nector.

3. Clean smoke alarm.

Smoke alarm beeps
once every 40 seconds

(KF10 and KF20 only)

(KF10R and KF20R )
item #3

1. Turn off power and replace

battery. See in the MAINTE-
NANCE AND CLEANING
section.

2. Clean smoke alarm.

3. Verify that unit has been

under mains operation for a
minimum of 2 full days. If
the beeping persists after
required charging period,
return the unit for service.

Smoke alarm sounds
unwanted alarms when
residents are cook-
ing,taking showers, etc.

Interconnected smoke
alarms do not sound
when system is tested.

1. Hire an electrician to move

smoke alarm to a new
location. See "SMOKE
ALARM PLACEMENT".

1. Press and hold test button

for at least three seconds
after the first unit sounds.

2. Hire an electrician to

ensure smoke alarms are
properly connected.

3 chirps every 40
seconds

Ten (10) year end of life warn-
ing.  Alarm must be replaced
(REPLACE IMMEDIATELY! )

1374-7205-00(KF10_KF20_KF10R_KF20R)_EN_V4:_  2014.11.20  10:16 AM  Page 7

Summary of Contents for KF10

Page 1: ...e lithium batteries that will last the life of the alarm and a tamper proof locking screw option Models KF10R and KF20R include permanent rechargeable lithium batteries Operating temperature 0 C to 40 C Operates up to 93 humidity non condensing IMPORTANT SAFETY INFORMATION PLEASE READ AND SAVE THESE INSTRUCTIONS W A R N I N G DO NOT paint or cover the smoke alarm with tape This smoke alarm should ...

Page 2: ...age injury or death that may result from fire If a household member is hearing impaired install special smoke alarms with lights or vibrating devices to alert occupants Smoke alarms can only sound their alarms when they detect smoke Smoke alarms detect combustion particles in the air They do not sense heat flame or gas This smoke alarm is designed to give audible warning of a developing fire Howev...

Page 3: ...utton is difficult e g top of stairwells Siting should be in accordance with the current Building Regulations and or BS5839 Pt6 current I E E Regulations CAUTION Alarm should not be exposed to dripping or splashing HOW TO INSTALL THIS SMOKE ALARM DANGER ELECTRICAL SHOCK HAZARD Turn off power at the main consumer unit or cir cuit breaker by removing the fuse or switching the circuit breaker to the ...

Page 4: ...not installed 14 Turn on power at main fuse box or circuit breaker The green LED on the cover should be illuminated 15 Test smoke alarm See TESTING THE SMOKE ALARM INTERCONNECTING SMOKE ALARMS Use 1 5mm2 minimum solid or stranded cable with a rating of 230V When interconnecting maximum cable length between any two is 450 m for 1 5mm2 or 1200 m for 2 5mm2 20 OHMS loop resistance NOTE Maximum length...

Page 5: ...hat a working battery is present 2 Firmly depress and hold the Push to Test button for at least five 5 sec onds The smoke alarm will sound a loud beep about three 3 times a second The alarm may sound for up to 10 seconds after releasing the Push to Test button NOTE If smoke alarms are interconnected all smoke alarms should sound an alarm within three seconds after any test button is pushed and the...

Page 6: ...These cells are designed to last the useful life of the smoke alarm C CL LE EA AN NI IN NG G Clean the smoke alarm at least once a month to remove dust dirt or debris Always turn off power to smoke alarm before cleaning Using the soft brush or wand attachment to a vacuum cleaner vacuum all sides and cover of smoke alarm Be sure all the vents are free of debris If necessary turn off power and use a...

Page 7: ...t sound when tested NOTE Push and hold test button for at least five 5 seconds while testing 1 Check that AC power is turned on Green LED should be illuminated 2 Turn off power Remove smoke alarm from mount ing plate and a check that connector plug is securely attached b check that battery is properly attached to con nector 3 Clean smoke alarm Smoke alarm beeps once every 40 seconds KF10 and KF20 ...

Page 8: ...ted Kingdom Tel 44 0 1753 685148 www smoke alarms co uk 8 Leading authorities recommend that both Ionisation and photoelec tric smoke alarms be installed to insure maximum detection of the various types of fires that can occur within the home Ionisation sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarm...