background image

5

LED Power/Alarm Indicator

The visual LED indicates the following:

Special Features of Model CC and CEC

Alarm Control

™ 

(Quick-Quiet) (Models CC and CEC only)

When activated, Alarm Control

(Quick-Quiet) quiets unwanted alarms for a maximum of 15  minutes.

Always check that the smoke alarm has activated in a false alarm situation. Be sure a real fire emergency
does not exist.
To use the Alarm Control

(Quick-Quiet) feature:

Press and release the test button during an unwanted alarm. The alarm should stop within ten seconds.
The LED will flash about once every 10 seconds. This means the smoke alarm is in Alarm Control

(Quick-

Quiet) mode. Just before returning to normal operation, the smoke alarm will sound two short beeps.
This signals the end of Alarm Control

(Quick-Quiet).

If the smoke alarm does not go into Alarm Control

(Quick-Quiet) and continues to sound its loud alarm

horn, the smoke is very heavy. This is possibly a dangerous situation—-take emergency action immediately.

Safety Light (Model CEC only)

Model CEC features a safety light. This light turns on when the smoke alarm sounds. The safety light is a
miniature lamp which will last up to 15 hours of continuous operation. Its purpose is to assist in provid-
ing light in the escape route during a fire.

If the safety light does not turn on when the smoke alarm is tested, check the batteries. Replace the
batteries if necessary.

IMPORTANT: Smoke alarms with the safety light require two (2) AA batteries to operate the safety light.
These batteries are in addition to the 9-volt battery used to operate the smoke alarm.

Battery Replacement

Replace battery at least once a year or immediately when the low battery signal (a chirp) sounds once a
minute. Use only the following batteries as replacements in this smoke alarm: Eveready 216, 522, 1222,
or Duracell MN 1604. Long Life Lithium replacement battery is Ultralife U9VL-J.

NOTE: For Model CEC, replace safety light batteries with two AA size batteries. Replace all  batteries at
the same time.

DO NOT USE ANY OTHER TYPE OF BATTERY, EXCEPT AS SPECIFIED IN THIS 
MANUAL. DO NOT USE RECHARGEABLE BATTERIES.

DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED.

1. Turn smoke alarm counter-clockwise to detach from mounting plate.

2. From back of smoke alarm, lift tab to open battery pocket door (Models CB and CC only). Remove bat-

tery from pocket. Disconnect and discard drained battery from battery connector.

3. Connect a fresh, 9-volt battery to connector. The battery will fit only one way. Be sure battery connec-

tor is securely attached to battery terminals.

NOTE: For Model CEC, replace safety light batteries with two AA size batteries. Replace all batteries at the
same time.

4. Push test button for at least five (5) seconds. The alarm horn should sound. This means the battery is

connected properly.

5. Place battery into battery pocket. Close battery pocket door. 

Push down until it snaps into place

.

6. Reattach smoke alarm to mounting plate. To do so, turn smoke alarm clockwise until it snaps into

mounting plate.

7. Test smoke alarm using test button as described on page 4, 

Testing Your Smoke Alarm

.

Maintenance and Cleaning

In addition to weekly testing, this smoke alarm requires yearly battery replacement, and periodic cleaning
to remove dust, dirt, and debris. Long Life Lithium model battery will last for the life of the alarm (approx-
imately ten years).

Cleaning

Clean the smoke alarm at least once a month to remove dust, dirt, or debris as follows:

• Using the wand attachment of a vacuum cleaner, vacuum all sides and cover of smoke alarm. Be sure

all the vents are free of debris.

• If necessary, remove battery and use a damp cloth to clean smoke alarm cover.

IMPORTANT: Do not attempt to remove the cover or clean inside the smoke alarm. THIS WILL VOID
YOUR WARRANTY.

Repair

DO NOT attempt to repair this smoke alarm. Doing so will void your warranty.

If smoke alarm is not operating properly, see 

Troubleshooting

. If you cannot solve the problem, and if

the detector is still under warranty, return smoke alarm to Maple Chase Company. Pack it in a well-
padded carton, shipping prepaid, to:

Maple Chase Company
2820 Thatcher Road
Downers Grove, IL 60515

If the smoke alarm is no longer under warranty, replace the smoke alarm immediately with a comparable
Firex

®

brand smoke alarm.

WARNING

!

Blinks once a minute

Normal operation–smoke alarm is receiving battery power

Blinks once a second

Smoke is detected; audible alarm will simultaneously sound

Models CC and CEC:

Blinks once every 10 seconds 

Alarm Control

(Quick-Quiet) is actively quieting an

unwanted alarm

CAUTION

!

CAUTION

!

111-281 English new  7/25/01  4:24 PM  Page 5

Summary of Contents for CC

Page 1: ... Procedures 7 Limited Warranty Table Of Contents CB CC CEC Ionisation type sensor Smoke Alarm Features Models CB CC and CEC are ionisation type smoke alarms Unique battery missing feature The smoke alarm will not attach to the mounting bracket if a battery is not in the battery pocket Low battery signal The smoke alarm will sound a short beep about once a minute if the battery needs to be replaced...

Page 2: ... a room should be further than 7 5m from the nearest smoke alarm This may require additional smoke alarms Where there are rooms other than bed rooms or toilets on either side of a bedroom a smoke alarm should be sited midway between the doors to these rooms For the highest level of protection install smoke or heat alarms in all other rooms except bath rooms or toilets FIGURE 1 Siting of Smoke Alar...

Page 3: ...t site an ionisation smoke alarm in an area where particles of combustion are normally present such as kitchens or garages An ionisation type smoke alarm with a FALSE ALARM CONTROL feature or a photoelectric type smoke alarm should be used to minimize nuisance alarms Do not site a smoke alarm in dusty or dirty areas SUCH AN INSTALLATION CANNOT BE RELIED UPON An accumulation of dust and dirt in the...

Page 4: ...es end to end into the battery pocket observing polarity 10 Position smoke alarm to mounting bracket and turn clockwise The smoke alarm will lock into place To engage tamper resist feature insert pin into notch on edge of smoke alarm and mounting plate NOTE Smoke alarm will not mount to bracket if battery is not installed 11 Test smoke alarm See Testing Your Smoke Alarm DO NOT connect this smoke a...

Page 5: ... from mounting plate 2 From back of smoke alarm lift tab to open battery pocket door Models CB and CC only Remove bat tery from pocket Disconnect and discard drained battery from battery connector 3 Connect a fresh 9 volt battery to connector The battery will fit only one way Be sure battery connec tor is securely attached to battery terminals NOTE For Model CEC replace safety light batteries with...

Page 6: ...m and on every level of the home Smoke may not reach the smoke alarm for many reasons For example if a fire starts in a remote part of the home on another level in a chimney wall roof or on the other side of a closed door smoke may not reach the smoke alarm in time to alert household members A smoke alarm will not promptly detect a fire EXCEPT in the area or room in which it is installed This smok...

Page 7: ...nship under normal residential use and service for a period of ten 10 years from date of purchase Maple Chase agrees to repair or replace at its option any defective smoke alarm or Ultralife U9VL J 9 volt bat tery when applicable provided that it is returned with postage prepaid and with proof of purchase date to Maple Chase This warranty does not cover damage resulting from accident misuse abuse ...

Reviews: