Instruction manual for installation and maintenance
Electric Tilting Cooker
CBRE40
GB-CBRE40-DU-00 Page
10 di 10
HOW TO PROCEED IF …
Warning! :
Problems and failures may occur even when the appliance is used properly. Here is
a list of the mist probably situations and controls that the operator should perform
to avoid applying to a service centre unnecessarily.
If the problem is not solved after the necessary controls, turn off the appliance
immediately, unplug it, cut off any supplies and apply to a service centre.
DISPLAY MSG
DESCRIPTION
Intervention of the safety thermostat:
apply to a service centre for assistance.
Overheating in the relay card.
Automatic intervention to save the appliance electric circuit.
The alarm stops automatically when the electric circuit temperature
return into the values pre-established (< 60°C).
Anomaly in the ventilation system:
Apply to a service centre for assistance.
Damaged temperature probe (message flashing):
Apply to a service centre for assistance.
Error in connection between relay Board and the keyboard tab.
(The possible presence of moisture in the relay Board):
apply to a service centre for technical assistance.
DEFECT/ANOMALY
OPERATION
THE KEYPAD DOES
NOT START
Verify any cut-off on the electric feed (main switch of the
electrical net).
Verify any accidental pressing of the emergency button,
otherwise:
Apply to a service centre for assistance.
THE VATT MOVEMENT IS
NOT POSSIBLE
Apply to a service centre for assistance.
THE HEATING SYSTEM
DOESN’T WORK
Verify that the vat must be in cooking position.
The led of the key
must be switched off otherwise:
Apply to a service centre for assistance.