background image

www.desatech.com

114924-01D

13

TROUbLESHOOTING

 WARNING: Turn off appliance and let cool before servicing. Only 

a qualified service person should service and repair heater.

 CAUTION: Never use a wire, needle or similar object to clean 

ODS/pilot. This can damage ODS pilot unit.

Note: 

All troubleshooting items are listed in order of operation.

POSSIBLE CAUSE

REMEDY

OBSERVED PROBLEM

1. Ignitor  electrode  not  con

-

nected to ignitor cable

2. Ignitor  cable  pinched  or 

wet

3. Broken ignitor cable

4. Bad piezo ignitor

5. Ignitor electrode positioned 

wrong or broken

1. Gas  supply  turned  off  or 

equipment  shutoff  valve 

closed

2. Control knob not in PILOT 

position

3. Control knob not pressed in 

while in PILOT position

4. Air  in  gas  lines  when  in

-

stalled

5. Depleted  gas  supply  (pro

-

pane/LP only)

6. ODS/pilot is clogged

7. External gas regulator setting 

is incorrect

When ignitor button is pressed, 

there is no spark at ODS/pilot

When ignitor button is pressed 

in  there  is  spark  at  ODS/pilot 

but no ignition

1. Reconnect ignitor cable

2. Free ignitor cable if pinched 

by any metal or tubing. Keep 

ignitor dry

3. Replace ignitor cable

4. Replace piezo ignitor

5. Replace  pilot  assembly  for 

remote-ready units;  replace 

ignitor electrode for variable 

manually controlled units

1. Turn on gas supply or open 

equipment shutoff valve

2. Turn control knob to PILOT 

position

3. Press in control knob while in 

PILOT position

4. Continue holding down con

-

trol knob. Repeat igniting op

-

eration until air is removed

5. Contact local propane/LP gas 

company

6. Clean ODS/pilot (see 

Cleaning 

and Maintenance

, page 12) or 

replace ODS/pilot assembly

7. Replace gas regulator

Summary of Contents for MVO18VNA

Page 1: ...t any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach...

Page 2: ...Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This a...

Page 3: ...nt even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Do not place log sc...

Page 4: ...eans screens shall have openings for introduction of combustion air 8 If fireplace has glass doors never operate with glass doors closed If you operate heater with doors closed heat buildup inside fir...

Page 5: ...used with vented decorative appliances Installation WARNING A qualified ser vice person must install heater Follow all local codes WARNING Before installing in a solid fuel burning fireplace the chim...

Page 6: ...le material and connected to a working flue The fireplace chimney must have a permanent vent opening to outside with minimum openings shown in Figure 3 Figure 2 Technical Information Chart Figure 3 Si...

Page 7: ...ollow all local codes WARNING This appliance requiresa3 8 NPT NationalPipe Thread inlet connection to the control valve CAUTION Never connect propane LP unit directly to the propane LP supply This uni...

Page 8: ...installed wrong heater may not run properly CAUTION Avoid damage to gas control Hold gas control with wrench when connecting it to gas piping and or fittings Figure 7 Gas Connection Purchasetheoptiona...

Page 9: ...Propane LP Gas Only Figure 10 Checking Gas Joints Natural Gas Only Equipment Shutoff Valve Gas Meter Control Valve Location Pressure Testing Appliance Gas Connections 1 Open equipment shutoff valve s...

Page 10: ...tch is in OFF position 3 Be sure gas line shut off valve is OPEN 4 Press in and turn control knob clockwise to the OFFposition see Figure 12 Note Knob cannot be turned from PILOT to OFFunless knob is...

Page 11: ...Setting the Selector Switch Control Knob and Flame Adjustment Knob for Remote Operation Selector Switch in REMOTE Position REMOTE OFF ON Piezo Ignitor Control Knob Flame Adjustment Knob Figure 14 On...

Page 12: ...Pattern Yellow Flames with Orange Streaks Cleaning and Maintenance WARNING Turn off the ap pliance and allow to cool before cleaning CAUTION You must keep control areas burners and cir culating air pa...

Page 13: ...gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 External gas regulator setting is incorrect When ignitor button is pressed there is no spark at ODS pilot When...

Page 14: ...n burner s see Cleaning and Maintenance page 12 1 Clean burner see Cleaning and Maintenance page 12 or replace burner orifice 2 Replace damaged burner 3 Replace gas regulator 4 Correct external gas re...

Page 15: ...oved from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installation clearances see page 6 4 Clean burners see Cleaning and Maintenance page 12 or replace bur...

Page 16: ...ding while heating or contracting while cooling 1 Appliance burning vapors from paint hair spray glues cleaners chemicals new carpet etc See IMPORTANT statement above 2 Low fuel supply propane LP only...

Page 17: ...will not stay lit burners will have delayed ignition Propane LPunits only propane LPgas supply may be low You may feel your gas pressure is too low If so contact your local propane LP or natural gas s...

Page 18: ...www desatech com 114924 01D 18 Illustrated Parts Breakdown Models MVO24VNA MVO24VPA MVO18VNA and MVO18VPA 1 2 3 4 5 6 17 16 15 7 8 9 10 11 12 14 13...

Page 19: ...01 Pilot Assembly 1 11 111828 01 Brass Fitting 1 111818 01 Brass Fitting 1 12 114930 01 Pilot Bracket 1 114930 02 Pilot Bracket 13 26205 Gas Orifice 1 23109 Gas Orifice 1 14 114936 02 Venturi 1 11493...

Page 20: ...installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of norm...

Reviews: