The bracket is attached to the pole using the U-bolt and one or two of the supplied jaw-clamps 
(top left in Figure  5). One jaw-clamp is used between the bracket and the pole; the second clamp 
may be used on smaller-diameter poles by placing it over the U-bolt before putting the U-bolt 
around the pole.

 

After placing the U-bolt around the pole, place the bracket over the legs of the U-bolt such that 
one leg passes through the round hole and the other leg passes through the curved slot. Snug the 
bracket slightly with the supplied nuts and lockwashers, but do not tighten until you have aligned 
the unit. The result should resemble Figure 8.

Figure 8. U-bolt Mounting Assembly

Aligning the HotClient

  The Alignment LED provides a visual indication of signal strength. Point the HotClient in the direc-

tion of its signal source, then carefully adjust it, both horizontally and vertically, using the Align-
ment LED as a guide. When you receive the strongest signal, tighten the nuts. Figure 9 shows how 
the bracket can be used to tilt the unit.

Figure 9. Tilting the Unit for Signal Alignment

Summary of Contents for HotClient 2100

Page 1: ...allation Guide are subject to change without notice Please refer to the Firetide partners web site partners firetide com for current versions Hardware Installation Guide HotClient 2100 2200 Customer P...

Page 2: ...etide be liable for any special incidental consequential punitive or indirect damages whatsoever including without limitation damages for loss of profits business interruption loss of informa tion or...

Page 3: ...HotClient needs power Note that the AC adapter has interchangeable inserts to fit most AC receptacles in the US Europe the UK Australia and elsewhere The adapter will operate on any voltage from 100...

Page 4: ...FAULT light comes on con tact your ISP Figure 3 Power Feed Unit Connections Connect the device to your PC or home network via the RJ 45 connector A crossover cable is NOT required Your Internet Servi...

Page 5: ...pre terminated the waterproof connector will pass an RJ 45 plug Figure 4 Series 2200 Outdoor Unit Package Contents Assembling the Ethernet Cable Test the unit before mounting it on the pole or mast B...

Page 6: ...ypically this is a Firetide HotPoint AP There is an external antenna connector but in most applications it is not needed Keep the plastic cover on this connected to prevent water from getting into the...

Page 7: ...rough the round hole and the other leg passes through the curved slot Snug the bracket slightly with the supplied nuts and lockwashers but do not tighten until you have aligned the unit The result sho...

Page 8: ...ith Firetide Software application Security Encryption WPA 64 128 256 w TKIP AES IEEE 802 1x LEAP Regulatory Agency Certifications Contact your Firetide dealer for product availability and certificatio...

Page 9: ...connector System indicator LEDs power status align Weight 2 lbs 0 9 Kg without bracket Dimensions 7 8 x 8 3 x 2 4 195 x 210 x 60 mm Bracket for pole and wall mounting One weatherized Ethernet transit...

Page 10: ...o ensure compliance with the FCC s RF exposure limits the antenna used for this transmitter must be installed to provide a separation distance of at least 70 cm from all persons and must not be co loc...

Page 11: ......

Reviews: