![FireplaceXtrordinair 36A-ZC Installation Instructions Manual Download Page 4](http://html1.mh-extra.com/html/fireplacextrordinair/36a-zc/36a-zc_installation-instructions-manual_2291981004.webp)
3
PREPARATION FOR ZERO CLEARANCE INSTALLATION
READ THIS ENTIRE MANUAL BEFORE INSTALLING THE NEW FIREPLACE. FAILURE TO
FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR
EVEN DEATH.
PACKING LIST:
Your Fireplace Xtrordinair 36A-ZC is packaged with the following items included:
¥
36A-ZC Fireplace
¥
Side Firebrick
¥
Grate
¥
Blower Assembly
¥
Flex Duct Ð 3' Length, 6" Diameter (For Blower System)
¥
Start Collar (For Blower System)
¥
Two (2) 12' Flex Ducts, 6" Diameter (For Cooling Vents)
¥
Two (2) Vent Hoods (For Cooling Vents)
¥
Two (2) Vent Hood Storm Collars (For Cooling Vents)
PREPARATION:
1.
Remove all tape and packaging.
2.
Remove the wood shipping frame from around and under the fireplace.
3.
Check that no parts have become loose and the fireplace has not been damaged during
shipping.
4.
Remove the hardware pack from the fireplace.
5.
READ THIS INSTALLATION MANUAL BEFORE PROCEEDING.
¥
Fireplace should be located such that no doors, drapes, furniture or other
combustibles can be placed close or swing closer than the minimum 36"
clearance.
¥
The fireplace must be installed in a level, secure position.
REQUIRED HEARTH:
The hearth must have a minimum size of 52" width by 20" depth of non-combustible material.
Certain other restrictions and exceptions apply. See the hearth section in the specifications
portion of the zero clearance installation instructions.
Chimney Height
Maximum
Minimum
Vertical
35 Feet
15 Feet
Before lifting the fireplace, consider removing some of the interior components to make it
lighter. Refer to the section "REPLACEMENT PARTS AND REMOVAL INSTRUCTIONS" in
the owner's manual for the proper sequence of removal and replacement of internal
components.