7.
6. Minimum distances from combustible or heat sensitive
materials:
The technical data sheet and the type board on the stove contain the data refer-
ring to the stove that might differ from these standard regulations.
In case of combustible floors, being sensitive to a rise in temperature, non-com-
bustible floor protector must be used. This floor protector must reach 50 cm
beyond the front (from the charcoal pan), 30 cm beyond the side (from the inner
wall of the combustion chamber) of the fireplace. The floor protector can be
made of metal or glass which can be chosen from the product list of FIRE-
PLACE accessories.
The given minimum safety distances from combustible or heat sensitive mate-
rials have to be kept by all means at the back, the front and sideways.
100 cm
20 cm
30 cm
20 cm
50 cm
20 cm
50 cm
I
found on the technical data sheet and the type board.
More information about safety distances from the connecting pipe can be found
at the description of connecting.