Encore Urban Wet
7
6. Assemble and install the flue as per instructions (page 9 & 10
).
7. Secure both the fire and floor protector to the floor by using
appropriate fastenings through the holes provided in the rear of the base
plate. This is a New Zealand Standard 2918 requirement due to NZ being
earthquake prone.
8. A flue shield must be fitted; the minimum requirement is for a single
skin, semi-circular, stainless steel flue shield with a reflective inner
surface 1200mm high. This should be installed so that the bottom edge of
the flue shield is 20mm from the top surface of the heater and spaced off
the flue pipe by approximately 35mm.
9. Lift granite ashlip onto the two securing screws fitted to the front of
the fire under the door and tighten the two screws to secure it. (Do not
attempt to lift the fire by the ashlip).
10. Carefully position the main slotted steel painted top panel onto the
heater, there are locating feet on the underside that fit into the indents on
the cast iron tops that ensure it is correctly positioned.
Slide in the rear infill top panel behind the flue outlet
and then the curved plate locates on the outer rear edge.
11. Fit door knob set to door lever arm as drawing
»»
Summary of Contents for Encore Urban wet
Page 10: ...Encore Urban Wet 10...