6.   Assemble and install the flue as per instructions (page 9 & 10

). 

 

7.   Secure both the fire and floor protector to the floor by using 
appropriate fastenings through the holes provided in the rear of the base 
plate.  This is a New Zealand Standard 2918 requirement due to NZ being 
earthquake prone. 
 
8.   A flue shield must be fitted; the minimum requirement is for a single 
skin, semi-circular, stainless steel flue shield with a reflective inner 
surface 1200mm high.  This should be installed so that the bottom edge of 
the flue shield is 20mm from the top surface of the heater and spaced off 
the flue pipe by approximately 35mm. 
 
9.   Lift granite ashlip onto the two securing screws fitted to the front of 
the fire under the door and tighten the two screws to secure it. (Do not 
attempt to lift the fire by the ashlip).  
 
10.  Carefully position the main slotted steel painted top panel onto the 
heater, there are locating feet on the underside that fit into the indents on 
the cast iron tops that ensure it is correctly positioned.   
Slide in the rear infill top panel behind the flue outlet  
and then the curved plate locates on the outer rear edge. 
 
11.   Fit door knob set to door lever arm as drawing 

»» 

 

 
 
 
 
 

Summary of Contents for Encore Urban wet

Page 1: ...stalled on properties of less than 2 hectares of land where the requirements are for fires which meet with NES standards of 1 5gm and 65 efficiency All installations must be in accordance with these i...

Page 2: ...No Topic 3 1 Warnings 4 2 Installation Responsibilities 4 3 Floor Protector Requirements 5 4 Installation Clearances 6 5 Assembly Instructions 7 6 Wetback Installation 9 7 Flue Installation 10 Minimum...

Page 3: ...DS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING Use caution when reloading with fuel Do NOT attempt to load fuel into the heater when the fire inside the stove is at or near its...

Page 4: ...OR REQUIREMENTS The heater should always be installed on top of its base due to high temperatures sustained over long periods The base must be anchored to both the floor protector and the floor for se...

Page 5: ...m the BASE of the Encore and not the top plate Dimension C specifically is shown from the base drawer front which gives a 300mm clearance from the door opening as required under NZ2918 CLEARANCES A B...

Page 6: ...clearances as shown in section 4 on page 5 6 Plumb in the wetback in accordance with accepted plumbing practises refer to section 7 page 8 Ensure the wetback is not pushed down or comes into contact w...

Page 7: ...so that the bottom edge of the flue shield is 20mm from the top surface of the heater and spaced off the flue pipe by approximately 35mm 9 Lift granite ashlip onto the two securing screws fitted to t...

Page 8: ...le with the shortest and straightest possible pipe run 2 The heater should be within 6 metres of the hot water cylinder the closer the better 3 The flow pipe from the heater to the cylinder must rise...

Page 9: ...ing screws 8 Place ceiling plate with folded edges upwards over heater spigot 9 Position the flue pipe into the heater spigot The flue pipe can either lowered from the top as a single unit or fed up f...

Page 10: ...Encore Urban Wet 10...

Page 11: ...imited Manufacturers of Lady Kitchener Bronte Coaster Contessa Royale Viking Zealandia Athena Forte Aqualux Deco Plaza Kompact 98 Niven Street PO Box 3231 Onekawa Napier Phone 06 8438260 Fax 06 843050...

Reviews: