Firenzo Encore Urban wet User Manual Download Page 6

Encore Urban Wet 

 

5.  ASSEMBLY INSTRUCTIONS 

 

1.   Remove all outer packaging and timber. 
 
2.   Remove slotted steel top plates from rear of heater and set aside, 
taking care not to scratch or damage the paint finishes. 
 
3.   Remove granite ashlip and door knob set from inside the firebox and 
set aside, taking care not to scratch or damage it. 

 

4.   Position unit onto floor protector ensuring it complies with the 
clearances as shown in section 4 on page 5. 
 
6.   Plumb in the wetback in accordance with accepted plumbing practises 
– refer to section 7 page 8.  Ensure the wetback is not pushed down or 
comes into contact with the baffle bricks or flue gas deflectors.  This will 
cause premature wear to the wetback and will not be covered by the 
manufacturer’s warranty.  
 
5.   Lift top casting and ensure baffle bricks and metal deflector are 
correctly located as diagram below with DEFLECTOR PLATE 
CENTRED and then replace top casting ensuring good seal down onto fire 
rope bed. 
 

REFER ITEM 5  - CHECK BAFFLE BRICK INSTRUCTIONS 

Summary of Contents for Encore Urban wet

Page 1: ...stalled on properties of less than 2 hectares of land where the requirements are for fires which meet with NES standards of 1 5gm and 65 efficiency All installations must be in accordance with these i...

Page 2: ...No Topic 3 1 Warnings 4 2 Installation Responsibilities 4 3 Floor Protector Requirements 5 4 Installation Clearances 6 5 Assembly Instructions 7 6 Wetback Installation 9 7 Flue Installation 10 Minimum...

Page 3: ...DS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING Use caution when reloading with fuel Do NOT attempt to load fuel into the heater when the fire inside the stove is at or near its...

Page 4: ...OR REQUIREMENTS The heater should always be installed on top of its base due to high temperatures sustained over long periods The base must be anchored to both the floor protector and the floor for se...

Page 5: ...m the BASE of the Encore and not the top plate Dimension C specifically is shown from the base drawer front which gives a 300mm clearance from the door opening as required under NZ2918 CLEARANCES A B...

Page 6: ...clearances as shown in section 4 on page 5 6 Plumb in the wetback in accordance with accepted plumbing practises refer to section 7 page 8 Ensure the wetback is not pushed down or comes into contact w...

Page 7: ...so that the bottom edge of the flue shield is 20mm from the top surface of the heater and spaced off the flue pipe by approximately 35mm 9 Lift granite ashlip onto the two securing screws fitted to t...

Page 8: ...le with the shortest and straightest possible pipe run 2 The heater should be within 6 metres of the hot water cylinder the closer the better 3 The flow pipe from the heater to the cylinder must rise...

Page 9: ...ing screws 8 Place ceiling plate with folded edges upwards over heater spigot 9 Position the flue pipe into the heater spigot The flue pipe can either lowered from the top as a single unit or fed up f...

Page 10: ...Encore Urban Wet 10...

Page 11: ...imited Manufacturers of Lady Kitchener Bronte Coaster Contessa Royale Viking Zealandia Athena Forte Aqualux Deco Plaza Kompact 98 Niven Street PO Box 3231 Onekawa Napier Phone 06 8438260 Fax 06 843050...

Reviews: