Firenzo Encore Urban wet User Manual Download Page 1

  
 
 
 

 
 
 
 
 

Please read this booklet and keep for future reference for the safe 

installation and operation of your: 

 

 

                               

Encore  

Urban wet

Urban wet

Urban wet

Urban wet

    MODEL

MODEL

MODEL

MODEL    

    

FREESTANDING WOODBURNER 

 
 

 
 
 
 

 
 
 
 
 
 
 
 
 

 

 

 
This URBAN fire can be installed on properties of less than 
2 hectares of land where the requirements are for fires which 
meet with NES standards of 1.5gm and  
65% efficiency.  

 

All installations must be in accordance 
 with these instructions.  Consult 
with the building authority having  
jurisdiction to determine the need for 
a permit prior to commencing the 
installation.  
 Failure to follow these instructions may also 
 void your fire insurance and warranty. 

Summary of Contents for Encore Urban wet

Page 1: ...stalled on properties of less than 2 hectares of land where the requirements are for fires which meet with NES standards of 1 5gm and 65 efficiency All installations must be in accordance with these i...

Page 2: ...No Topic 3 1 Warnings 4 2 Installation Responsibilities 4 3 Floor Protector Requirements 5 4 Installation Clearances 6 5 Assembly Instructions 7 6 Wetback Installation 9 7 Flue Installation 10 Minimum...

Page 3: ...DS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING Use caution when reloading with fuel Do NOT attempt to load fuel into the heater when the fire inside the stove is at or near its...

Page 4: ...OR REQUIREMENTS The heater should always be installed on top of its base due to high temperatures sustained over long periods The base must be anchored to both the floor protector and the floor for se...

Page 5: ...m the BASE of the Encore and not the top plate Dimension C specifically is shown from the base drawer front which gives a 300mm clearance from the door opening as required under NZ2918 CLEARANCES A B...

Page 6: ...clearances as shown in section 4 on page 5 6 Plumb in the wetback in accordance with accepted plumbing practises refer to section 7 page 8 Ensure the wetback is not pushed down or comes into contact w...

Page 7: ...so that the bottom edge of the flue shield is 20mm from the top surface of the heater and spaced off the flue pipe by approximately 35mm 9 Lift granite ashlip onto the two securing screws fitted to t...

Page 8: ...le with the shortest and straightest possible pipe run 2 The heater should be within 6 metres of the hot water cylinder the closer the better 3 The flow pipe from the heater to the cylinder must rise...

Page 9: ...ing screws 8 Place ceiling plate with folded edges upwards over heater spigot 9 Position the flue pipe into the heater spigot The flue pipe can either lowered from the top as a single unit or fed up f...

Page 10: ...Encore Urban Wet 10...

Page 11: ...imited Manufacturers of Lady Kitchener Bronte Coaster Contessa Royale Viking Zealandia Athena Forte Aqualux Deco Plaza Kompact 98 Niven Street PO Box 3231 Onekawa Napier Phone 06 8438260 Fax 06 843050...

Reviews: