background image

Lift out foam packed hardware

3-Installation

IMPORTANT:

 

You must read the installation and owner’s manual provided with the grill.

These quick start instructions assume a 

natural gas or household propane

 configured unit. 

See main instructions for propane cylinder units.

Note:

  This section is only an overview of installation to the gas supply. Refer to the grill owner’s manual for complete grill installation details.

Run the attached flex connector routed under the left side of the grill to the gas stub. 

Turn OFF the gas supply at the source. 

Then connect the flex connector 

to the gas supply (Fig. 3-3). Use a pipe joint compound resistant to all gasses on all male fittings except flare fittings.  
Turn all burner control knobs to the 

OFF

 position. Turn the gas supply on. Then carefully check all gas connections for leaks with a brush and half-soap/half-water 

solution before lighting. 

NEVER USE A MATCH OR OPEN FLAME TO TEST FOR LEAKS.

 

The control panel must be flush with the enclosure face as shown in Fig. 3-4.
Proper grill airflow must be maintained as shown in Fig. 3-5. Do not block. 

It is not necessary to remove the control panel or knobs for installation.

Refer to the INSTALLATION REQUIREMENTS section of your grill owner’s manual 
for complete details.

CAUTION: 

Wind blowing into or across the rear oven lid vent (Fig. 3-1) 

can cause poor performance and/or dangerous overheating. 
Orient the grill so that the prevailing wind blows toward the 
front of the grill (Fig. 3-2).

CAUTION: 

To prevent dangerous overheating, the rear of the unit must have a 

minimum clearance of 4” from any backsplash/non-combustible wall.

INSTALLER:  

Leave these instructions with consumer.     

CONSUMER: 

Retain for future reference.

This grill must be installed in accordance with local codes and ordinances, or, in the absence of local codes, with either the latest National Fuel Gas Code (ANSI  

Z223.1/NFPA 54), and Natural Gas and Propane Storage and Handling Installation Code (CSA-B149.1).
This appliance and its individual shutoff valves must be disconnected from the gas-supply piping system when testing the system at pressures in excess of ½ psig. 

This appliance must be isolated from the gas-supply piping system by closing its dedicated manual shutoff valve during any pressure testing of the gas-supply 

system at pressures up to and including ½ psig.

This grill is designed for outdoor use only. 

 

DO NOT use this grill inside a building, garage, or enclosed area (see paragraph below). DO NOT use this grill 

in or on a recreational vehicle or boat.
Important:     If installing this grill in a COMBUSTIBLE enclosure, the correct RHP insulating liner must be used. Consult the liner instructions for  

 

         cut-out dimensions and installation.

A minimum 5 foot clearance is required between the countertop and the overhead construction. When installed under combustible overhead construction, the area 

above the cooking surface of the grill 

must

 be covered with an exhaust hood. The exhaust hood provides the protection for the combustible overhead construction. 

DO NOT use this appliance under unprotected combustible overhead construction

.When installed under overhead non-combustible construction, an exhaust 

hood is highly recommended. 

When using an exhaust hood:

 the area above the cooking surface of the grill must be covered with a hood larger than the cooking 

area of the grill, and with a minimum of 1200 CFM (cubic feet per minute) for proper outdoor application.

2-Unpacking

Carefully unpack the grill, removing all packing material and protective film (including the 
clear film on the drip tray). Verify that all parts have arrived undamaged by consulting the 
parts list in the owner’s manual. Remove foam packed hardware from oven area. (See 
Fig. 2-1.) 

Consult the parts list in the owner’s manual. If any parts are missing or damaged, 
immediately contact the Fire Magic dealer before beginning installation.

Fig. 2-1

1-Safety

Remove plastic 

zip-ties

Location

Connect Gas supply

Installation must be performed by a qualified professional service technician.

CAUTION:  WHEN INSTALLING UNIT, BE AWARE OF 

GRILL ENCLOSURE / VENTILATION REQUIREMENTS

YOU MUST VENT

 UNIT IN ACCORDANCE WITH YOUR OWNER’S MANUAL. FAILURE TO DO SO MAY 

RESULT IN A FIRE OR EXPLOSION CAUSING PROPERTY DAMAGE, BODILY INJURY, OR DEATH.

REV 6 - 1804201515

L-C2-335

Built-in Outdoor

Gas Grill Quick Start Guide

ECHELON

diamond series

Fig. 3-2

CORRECT

PLACE GRILL SO PREVAILING WIND 

BLOWS TOWARD FRONT OF GRILL

OFF

Shut-off valve (shown in-line) 
must be within 6 feet of the unit

To gas 

system

(Cut-out)

Pipe 

adapter 

fitting

(Countertop)

Gas inlet pipe

Flex 

connector

Hanger

Top View

Maintain proper 

ventilation airflow

Fig. 3-4

Control panel 

must be flush with 

enclosure face

Countertop

Overhang

Fig. 3-3

Fig. 3-5

Required shut-off valve (shown in-line) 
must be within 6 feet of the unit 

YOU MUST PROTECT REAR OVEN 

VENT FROM PREVAILING WIND

Rear oven lid vent

INCORRECT

Fig. 3-1

Reviews: