Fireline FGi Installation And Operating Instrictions Download Page 3

 

2

 

FGi.FPi.FXi 

Issue

 08 03/13 

1. List of Components 

 
Description of Parts 

 

 

Qty 

 
FXi/FPi Stove Assembly   

 

Multi Tool 

 

 

 

 

Ash Pan  

 

 

 

 

 

Flue Spigot Collar   

 

 

Spigot Collar fixing screws  

 

Stove Operating Glove 

 

 

 

 

2. Component Identification and Assembly 

Your stove comes packed in a plywood crate. Carefully remove the straps and lift 

off the upper crate. Remove any plastic packaging, open the door and remove all 

the contents. See List of Components section and check contents carefully. 

2.1 To remove the baffle plate, first remove the fuel retainer by lifting it up and out the 

front of the stove. Remove the firebox base liners, the two side liners and the rear 
liner. Handle & store very carefully to one side where they will not get broken. 

2.2 Now the baffle plate can be removed by lifting off its supports and bringing out 

through the firebox door opening. 

2.3 It is sometimes useful to remove the door at this stage by opening and lifting up to 

slide the hinge pins out. 

2.4 Remove the 2 x screws securing the primary air control/grate shaker rod fascia plate 

from under the firebox. Lift up the rear of the whole grate assembly and slide up and 
out of the opening in the base of the firebox. Do not dislodge or remove the seal 
fitted under it. 

2.5 Now proceed to install the stove according to these instructions and current 

installation standards or HETAS advice. The internal parts of the stove can be re-
assembled as the reverse of the previous removal instructions. 

 

 

 

Fig 2 

– FGi/FXi/FPi 5, FGi/FXi/FPi 5W, FGi/FXi/FPi 8  Stove Assembly and 

controls 

Fig 1 - Multi Tool Details 

Summary of Contents for FGi

Page 1: ...on of Charlton Jenrick Ltd Unit D Stafford Park 2 Telford Shropshire TF3 3AR T 0845 519 5991 F 0845 519 5992 A Charlton and Jenrick Group Company DEFRA Clean Air Act Exemption The FGi FXi FPi 5 FGi FXi FPi 5W and FGi FXi FPi 8 Inset stoves have been exempted under the Clean Air Act 1993 to burn seasoned wood logs in designated smokeless zones in the UK This is subject to the correct fitting of the...

Page 2: ...nformation 3 4 Installation Information 4 4 1 Chimney 4 4 2 Ventilation 5 4 3 Flue Draught 5 4 4 Connection to Chimney 5 4 5 Fixing 5 4 6 Material Clearances 5 4 7 Hearths 6 4 8 Commissioning Handover 6 5 Technical Data 7 6 Operating Instructions 7 6 1 Clean Air Act 7 6 2 Air controls 8 6 3 Cleaning 9 6 4 Fuels 9 6 5 Important Notes for Wood Burning 9 6 6 Lighting the stove 10 6 7 Re fuelling 10 6...

Page 3: ...lly to one side where they will not get broken 2 2 Now the baffle plate can be removed by lifting off its supports and bringing out through the firebox door opening 2 3 It is sometimes useful to remove the door at this stage by opening and lifting up to slide the hinge pins out 2 4 Remove the 2 x screws securing the primary air control grate shaker rod fascia plate from under the firebox Lift up t...

Page 4: ... 3 1 2 Important Chimney Warning This stove must not be installed into a chimney that serves any other heating appliance 3 1 3 Extractor Fan Warning There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room If unavoidable the appliance must be checked with A D 1 21 and necessary action taken 3 1 4 Cleaning and Chimney Sweeping T...

Page 5: ...ourse of installation then please seek specialist guidance and use appropriate protective equipment 3 1 12 Metal Parts When installing or servicing this stove proper care should be taken to avoid the possibility of personal injury 4 0 Installation Information 4 1Chimney The chimney height and the position of the chimney terminal should conform to Building Regulations Minimum chimney height is 4 5m...

Page 6: ...operly fitted into the fireplace opening by back filling with 6 1 ratio vermiculite cement mixture using minimal water through the top of the fireplace or flue spigot opening The surface should be finished using 1 1 8 mix of cement lime and sand The connecting pipe is fitted with the spigot pushed up from inside the stove and rotated onto its keyhole slots to join to the pipe Ensure that the pipe ...

Page 7: ...early defined edge change of level to discourage placing of any combustible materials on or partially over it Ensure the hearth is flat level and the back panel and surround are at right angles to the hearth The appliance shall be installed on a floor with adequate load bearing capacity If the existing construction does not meet this requirement suitable measures e g load distributing plate should...

Page 8: ...pray on or near the stove when it is alight 6 1 The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to ac...

Page 9: ... is controlled through a slider assembly located on the top centre of the stove If you want clean glass always leave this control open some way whilst burning unless the stove is being shut right down for a long period Moving towards the mark increases the burn rate whilst moving towards the mark reduces it The DEFRA air restrictor will deliberately prevent full closure of this control Tertiary Ai...

Page 10: ...the recommended fuel For any other fuels please contact the manufacturer for advice Warning Petroleum coke fuels or household waste must not be burnt on this appliance Should any difficulties arise over fuel quality or suitability consult your local approved fuel merchant 6 5 Important Notes for Wood burning With a full load of wood and burning at a moderate rate the stove will typically need to b...

Page 11: ... maximum heat output This is to allow the paint to cure in steadily and to give a long service life of the paint finish During this curing in process you may notice an unpleasant smell whilst the finishes finally cure It is non toxic but for your comfort we would suggest that during this period you leave all doors and windows open First open the secondary air wash control fully Load the firebox wi...

Page 12: ... remain very hot for a considerable time after the fire has died down or been extinguished 6 9 Shut down for prolonged periods If the stove is to be left unused for a prolonged period of time then it should be given a thorough clean to remove ash and unburned fuel residues To enable a good flow of air through the appliance to reduce condensation and subsequent damage leave the air controls fully o...

Page 13: ...identified and corrected If necessary seek professional advice from chimney or stove specialists Important Do not fit an extractor fan in the same room as this appliance IN THE EVENT OF A CHIMNEY FIRE Raise the alarm to let others in the house know Call the Fire Service Reduce the appliance burning rate by closing all air controls fully Move furniture and rugs away from the fireplace and remove an...

Page 14: ...13 FGi FPi FXi Issue 08 03 13 8 1 FGi FPi 5 Inset Stove Dimensions ...

Page 15: ...14 FGi FPi FXi Issue 08 03 13 8 3 FGi FPi 8 Inset Stove Dimensions 8 2 FGi FPi 5W Inset Stove Dimensions ...

Page 16: ...cal Fireline stove retailer will be pleased to supply spare parts and to provide any other information you require Alternatively contact Fireline 7 Can the doors be left open while burning For safety and heat efficiency the doors should remain closed 8 Why is the stove smoking when lit A flue with back draught problems is almost certainly the cause of a smoking stove Also check adequate ventilatio...