GUIDE TO

Lights & 

Sounds

Smoke & Heat Alarms

POWER IS OK

 Red LED flashes 

 every minute followed by

a single beep   after 10 seconds if the battery power is weak

GENERAL FAULT 

Double beep 

 every minute

TEST BUTTON JAMMED 

Single beep 

 every 11 seconds 

TEST 

Red LED flashes 

 twice every second, plus a series of three beeps 

ALARM SILENCE

 

Red LED flashes 

 once every 10 seconds

FULL ALARM

 Red LED flashes 

 twice every second  

plus a series of three beeps 

 every 4 seconds

EVACUATE THE PROPERTY IMMEDIATELY AND CALL THE EMERGENCY SERVICES!

FH150/155/160

Compact design

&

TSE-Technology

FHB10

FEATURING

X-Profile

&

TSE-Technology

FHB10W

FEATURING

X-Profile

&

TSE-Technology

FHH10

FEATURING

Advanced

THERMISTOR 

Protection

FHH10W

FEATURING

Advanced

THERMISTOR 

Protection

Summary of Contents for FH150

Page 1: ...the design or specification details without prior notice REF COL S 01 2021 Important information FH150 155 160 Compact design TSE Technology FHB10 FEATURING X Profile TSE Technology FHB10W FEATURING X Profile TSE Technology FHH10 FEATURING Advanced THERMISTOR Protection FHH10W FEATURING Advanced THERMISTOR Protection FireHawk Smoke and Heat Alarms have a LOW BATTERY SILENCE Feature Pressing the TE...

Page 2: ...Do NOT place in insect infested areas attics garages etc use heat alarms there KEEP 300mm AWAY from lights that generate heat Tungsten and low voltage bulbs KEEP AWAY from objects that could divert or prevent smoke from reaching them ie beams and other ceiling features REMEMBER heat alarms need a fire to activate flames WILL be present Do NOT install on walls Do NOT use in escape routes ALWAYS int...

Page 3: ...REMOVING ALARM FROM BASE Fireangel base adaptor DICON base adaptor KIDDE base adaptor Plugs and screws Sticky pads Adhesive Often you ll find old bases from other smoke and heat alarm manufacturers perminantly fixed to ceilings We can provide you with base plate adaptors so that you can easily install FireHawk alarms to existing bases We recommend these three ways to fix your smoke or heat alarm b...

Page 4: ...x months clean the alarm with a damp cloth do not use spray or chemical cleaners and polishes In the event of a problem contact our helpline 0800 008 6568 TROUBLE SHOOTING Be sure which alarm has been the problem upstairs downstairs heat or smoke Are the alarms interlinked If so check which one has a fast flashing red light during an alarm that s the one that has set the system off Where is it ins...

Page 5: ... if the battery power is weak GENERAL FAULT Double beep every minute TEST BUTTON JAMMED Single beep every 11 seconds TEST Red LED flashes twice every second plus a series of three beeps ALARM SILENCE Red LED flashes once every 10 seconds FULL ALARM Red LED flashes twice every second plus a series of three beeps every 4 seconds EVACUATE THE PROPERTY IMMEDIATELY AND CALL THE EMERGENCY SERVICES FH150...

Reviews: