Linear Outdoor Fire (LOF)

REFERENCE

GAS PIPE SIZING

Length of Pipe in Feet

1/2”

3/4”

1”

1 - 1/4”

1 - 1/2”

2”

2 - 2 1/2”

3”

4”

10

275

567

1071

2205

3307

6221

10140

17990

35710

20

189

393

732

1496

2299

4331

7046

12510

25520

30

152

315

590

1212

1858

3465

5695

10110

20620

40

129

267

504

1039

1559

2992

4778

8481

17300

50

114

237

448

913

1417

2646

4343

7708

15730

60

103

217

409

834

1275

2394

3908

6936

14150

70

89

185

346

724

1086

2047

3329

5908

12050

80

78

162

307

630

976

1811

2991

5309

10830

90

69

146

275

567

866

1606

2654

4711

9613

100

63

132

252

511

787

1496

2412

4281

8736

125

54

112

209

439

665

1282

2083

3618

7382

150

48

100

185

390

590

1138

1808

3210

6549

175

43

90

168

353

534

1030

1637

2905

5927

200

40

83

155

325

491

947

1505

2671

5450

300

37

77

144

303

458

887

1404

2492

5084

NATURAL GAS : PIPE SIZING CHART

Natural Gas (NG) flow is given in 
thousands of BTU/hr. = 1 cubic 
foot of NG gas - 1000 BTU

Nominal pressure at the burner 
for Natural Gas is 3.5” of water 
column. (Typical machine supply 
5”-7”)

Pipe length must include 
additional length for all fittings. 
Add approximately 5 feet of pipe 
per fitting.

Natural Gas Example: A machine 
with a burner that requires 
440,000 BTU would need a 1 -1/4” 
pipe for a 20” long run. 

LIQUID PROPANE : PIPE SIZING CHART

NOTE: The sizing charts above list the specific pipe sizes required for the amount of BTU’s for a new gas line installations. If you 
are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper 
pressure. 

This chart is for reference only, we recommend you consult with a Licensed Plumber/Gas Fitter or NFPA54 (National Fuel 

Gas Code - current edition) for more details.

Length of Pipe in Feet

1/2”

3/4”

1”

1 - 1/4”

1 - 1/2”

2”

2 - 2 1/2”

3”

4”

10

108

230

387

793

1237

2259

3640

6434

-

20

75

160

280

569

877

1610

2613

5236

9521

30

61

129

224

471

719

1335

2165

4107

7859

40

52

110

196

401

635

1143

1867

3258

6795

50

46

98

177

364

560

1041

1680

2936

6142

60

42

89

159

336

513

957

1559

2684

5647

70

38

82

149

317

476

896

1447

2492

5250

80

36

76

140

239

443

840

1353

2315

4900

90

33

71

133

275

420

793

1288

2203

4667

100

32

68

126

266

411

775

1246

2128

4518

125

28

60

117

243

369

700

1143

1904

4065

150

25

54

105

215

327

625

1008

1689

3645

175

23

50

93

196

303

583

993

1554

3370

200

22

47

84

182

280

541

877

1437

3160

300

17

37

70

145

224

439

686

1139

2539

Liquid Propane (LP) Gas flow is 
given in thousands of BTU/hr.  =
1 cubic foot of LP gas - 2500 BTU.

This chart refers to low pressure LP, 
after regulation, Standard nominal 
pressure at the burner for Liquid 
Propane Gas is 11” of water column.

Pipe length must include additional 
length for all fittings. Add 
approximately 5 feet of pipe per 
fitting.

LP Example: A machine with a 
burner that requires 440,000 BTU 
would need a 1” pipe for a 20’ long 
run. 

GAS PIPE SIZING CHART

Table 4:

  Gas Pipe Sizing Chart

Summary of Contents for LOF-30MTN

Page 1: ...IANCE Warning For Outdoor Use Only PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE INSTALLATION PRECAUTION This Linear Outdoor Fire pit requires a minimum 18 square inches per side of cross ventilation Failure to provide proper ventilation can void the warranty Natural Gas Description LOF 30MT N 30 inch stainless tube burner pan LOF 36MT N 36 inch stainless tube burner pan MODELS ...

Page 2: ...ve unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adjustment alteration service or maintenance can cause injury of property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING If the information in these instructions is not fo...

Page 3: ...impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE Extra caution should be taken when lighting a fireplace when heavy rains high humidity and moisture are present Light the fireplace leave the area allowing any moisture in the media to dissipate We strongly recommend that during t...

Page 4: ...1 0 WC Max Inlet 10 5 WC 13 0 WC Table 3 Gas Pressures Model Min Max Opening Width Length A Pan Depth B Outside Pan C Inside Pan D Ground Level E Combustible Floor LOF 30MT N 6 7 W x 30 31 L 2 32 x 8 30 x 6 6 18 LOF 36MT N 6 7 W x 36 37 L 2 38 x 8 36 x 6 6 18 Note Linear Outdoor Fire s are rated at maximum Btu s which is dependent upon proper gas pipe sizing Flex line size also affect Btu s As a r...

Page 5: ...red for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure This chart is for reference only we recommend you consult with a Licensed Plumber Gas Fitter or NFPA54 National Fuel Gas Code current edition for more details Length of Pipe in Feet 1 2 3 4 1 1 1...

Page 6: ...ound the pipe with weather sealant 3 the primary shut off not supplied will reguire a 1 2 male flared fitting to enable connection of stainless steel flex IMPORTANT Installation of Natural or LP gas should be done by a qualified installer service agency or gas supplier The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of t...

Page 7: ...y Not approved for any indoor use 9 This Linear Outdoor Fire is designed to have Lava Rock Media completely covering the burner tube so that the burner is invisible Do not cover more than 1 above the top of the burner When purchasing Lava Rock it is recom mended to use minimum of 1 diameter as a base to fill the burner pan Decorative glass covering may be loosely scattered on top of the rock if de...

Page 8: ...s rated Teflon tape wrapped around the threads Thread the OAS orifice air shutter on to the nipple of the burning spur clockwise manner Secure into position See Fig 4 GAS FLOW Burner Pan OAS U3 8D S Lock Nut INSTALLATION OF LAVA ROCK MEDIA INTO BURNER PAN Install lava rock media into the burner pan Ensure the media is a minimum of 1 inch diameter for proper operation Note Do not pour Lava Rock dir...

Page 9: ...ds Key Valve Key Fig 6 Typical Installation Key Valve Flange Non Combustible Wall Material Non Combustible Wall Material Key Valve Primary Gas Supply Key Valve Side View Det a i l Note A 1 x 2 black iron or galvanized coupler nipple not supplied can be used as a spacer between the manual valve and the valve flange to add additional support to hold the manual key valve in place Key Valve Flange Non...

Page 10: ... Key Valve U1 8D S U1 8D S Fitting Inlet Gas Supply Expanded View of Match Throw LOF Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threads not flared fittings Ensure all connections are tight and check for gas leaks before and after assembly is complete Not Supplied ...

Page 11: ...ting air passageways of the appliance be kept clean 5 Inspect the fuel supply connection before each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause sever burns if contacted 2 Do not burn any solid fuels in this appliance MATCH ...

Page 12: ...1 WASHER10SS 5 1 2 Flex Gas Line 46 inch Length T 200 9898 46 6 Orifice Air Shutter LOF 30 NG 1 OAS NG36 6 Orifice Air Shutter LOF 30 LP 1 OAS LP49 6 Orifice Air Shutter LOF 36 NG 1 OAS NG29 6 Orifice Air Shutter LOF 36 LP 1 OAS LP41 7 Std Capacity Straight Ball Valve 1 BVL2S 8 12 inch Chrome Key for BVSL2S KEY PC 12 9 Chrome Flange decorative chrome cover for BVSL2S 1 CVR BVL2CP 10 1 2 MIP Brass ...

Page 13: ... the surface of logs if installed during heavy use Sooting may also occur periodically on the screen of the ignitor hood To clean brush off with a dry bristle brush or cloth Keep soot away from clothing of furniture 6 Over time stainless steel parts discolor when heated usually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance TROUBLE SHOOTING ...

Page 14: ...tion into the enclosure Model VENT 6X12SS LP Converstion Kits Model OAS 49 for LOF30 Model OAS 41 for LOF36 LIDS Stainless steel cover to protect fire pit when not in use Model LID LOF30 Model LID LOF36 Flexframe Universal brackets to support fire pit disc when using paver blocks or other non combustible enclosures Model FLEXFRAME SS Note Media such as Lava Rock or Lava Stoves are not supplied but...

Page 15: ...ther location or failure to perform normal and routine maintenance Damage due to severe weather conditions such as hail hurricanes earthquakes tornadoes discoloration due to over heating exposure to chemicals including salt either directly or in the atmosphere or very high humidity is not covered by this Limited Warranty There are no other express warranties except as set forth herein For consumer...

Page 16: ... Number ___________________________ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 ...

Reviews: