REV. D      Page 1

Outdoor Round Pan & Flat Disc Fire Pits 

with All Weather System (AWS)

Installation and Operating Instructions

IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS 

DO NOT  ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE

DO NOT DISCARD.  THIS MANUAL 

HAS IMPORTANT OPERATING AND 

MAINTENANCE INSTRUCTIONS.  

LEAVE WITH THE HOMEOWNER

.

MODEL:
SERIAL #:

Warning:

  For Outdoor Use Only

INSTALLATION PRECAUTION

 

This system requires a minimum 18-square inches (per side) of cross ventilation. 

Failure to provide proper ventilation will void the warranty.

Certified by 

Lab Test Certification

 for USA and 

Canada. Meets: ANSI Z21.972014, CSA C22.2 No. 

3-M1998 (R2014).

Natural Models

Propane Models

Description

FPB-29RBSAWS-N

FPB-29RBSAWS-P 25” Round Pan with 22” Spur Burner

FPB-33RBSAWS-N

FPB-33RBSAWS-P 33” Round Pan with 31” Spur Burner

FPB-26DBSAWS-N

FPB-26DBSAWS-P 26” Round Flat Disc with 22” Spur Burner

FPB-29DBSAWS-N

FPB-29DBSAWS-P 29” Round Flat Disc with 22” Spur Burner

FPB-34DBSAWS-N

FPB-34DBSAWS-P 34” Round Flat Disc with 31” Spur Burner

FPB-39DBSAWS-N

FPB-39DBSAWS-P 39” Round Flat Disc with 36” Spur Burner

FPB-44DBSAWS-N

FPB-44DBSAWS-P 44” Round Flat Disc with 36” Spur Burner

PN#90070

Round Pan Drop In

Round Flat Disc

Summary of Contents for FPB-26DBSAWS-N

Page 1: ...e proper ventilation will void the warranty Certified by Lab Test Certification for USA and Canada Meets ANSI Z21 972014 CSA C22 2 No 3 M1998 R2014 Natural Models Propane Models Description FPB 29RBSAWS N FPB 29RBSAWS P 25 Round Pan with 22 Spur Burner FPB 33RBSAWS N FPB 33RBSAWS P 33 Round Pan with 31 Spur Burner FPB 26DBSAWS N FPB 26DBSAWS P 26 Round Flat Disc with 22 Spur Burner FPB 29DBSAWS N ...

Page 2: ...e vicinity of this or other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage personal injury ...

Page 3: ...umidity and moisture are present Light the fire feature leave the area allowing any moisture in the media to dissipate We strongly recommend that during this drying out time that you monitor the fire feature from a distance This drying out period should be no less than 30 minutes Continue monitoring the flame from distance to ensure that all popping has ceased before fully enjoying the fire CAUTIO...

Page 4: ...al Gas and 11 0 WC for Liquid Propane LP at the burner orifice when using Firegear Outdoors Burning Spurs If you use a burner other than a Burning Spur Btu s will vary Note Flex line size and proper gas pipe sizing will also affect Btu s As a result your Btu s may vary slightly from Table 2 specifications Fig 2 Clearance to Combustibles Not to be used in an enclosed space Model Natural Gas Model P...

Page 5: ...local codes for proper procedures If pipe is to pass through a foundation or house wall make sure to seal the area around the pipe with weather sealant Consult a plumber for proper installation to ensure you are providing adequate gas supply for your application 4 Do not place an LP tank inside any fire pit enclosure Locate all Liquid Propane LP tanks outside the enclosure 5 To prevent performance...

Page 6: ...izes required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure This chart is for reference only we recommend you consult with a Licensed Plumber Gas Fitter or NFPA54 National Fuel Gas Code current edition for more details Length of Pipe in Feet 1 2...

Page 7: ...ut connections and connectors to prevent moisture issues from the outdoor environment The AWS system is polarity sensitive There is a red sleeve attached to the positive side of the GOE 30VDC adapter When wiring the remote control receiver one red wire from the receiver connects to the adapter with the red sleeve The other red wire of the receiver connects directly to the red wire from the gas val...

Page 8: ...e of the orifice to provide a cleaner flame See Fig 4 ELECTRICAL INFORMATION Wire Gauge Is the wire gauge correct Wiring must be 12AWG or greater solid or stranded for all installations Note It is recommended to fill the wire nuts with either dielectric grease or silicone prior to installing the wire nut This will ensure a waterproof connection Why GFI circuit A GFI is a type of circuit breaker wh...

Page 9: ...talled inside the enclosure due to the wire length limitations The power cord is 3 feet long the 30VDC leads to the valve are 3 feet long See Fig 5 Fig 5 Example of a single fire feature install with power supply and switch contained within the enclosure when applicable Note Must be 10 feet or more from a pool spa for this installation See additional illustration on page 10 Fig 8 ...

Page 10: ...nnection needed for the installation See Fig 20 INSTALLING KEY VALVE Note A 1 x 2 black iron or galvanized coupler nipple not supplied can be used as a spacer between the manu al valve and the valve flange to add additional support to hold the manual key valve in place if needed See Fig 21 Key Valve Flange Non Combustible Wall Material Non Combustible Wall Material Key Valve Black Iron Nipple Fig ...

Page 11: ...hand ensures no excessive dust from bag lays in the bottom of pan and potentially plugs the burner port holes or the pan weep holes IMPORTANT DO NOT PLACE ROCK OVER TOP OR UNDER THE PILOT SCREEN COVER The screen must be free of any debris to ensure proper lighting of burner and good flame sense See Fig 22 Cover the burner completely with media but do not make the depth greater than 1 inch over top...

Page 12: ... system with optional1420 A remote control LEARN Weather Proof Box AWS Valve Box GFI Box GOE 30VDC Power Supply FG 1420 A OD Receiver Power Wire to Valve Gas Supply Non Combustible Enclosure Burner Weather Proof Box Red GOE 30VDC Power Supply Heat Shield 120VAC Power GFI Outlet Orifice Flat Pan Pilot Switch Switch Side View Close Up To Valve Box To GOE 30VDC Black WIRING DIAGRAM FOR OPTIONAL REMOT...

Page 13: ...atural or LP gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance READ ALL LIGHTING INSTRUCTIONS BEFORE ATTEMPTING TO LIGHT FIRE PIT CAUTION ENSURE YOU HAVE LEAK TESTED THE FIRE PIT BEFORE OPERATING WARNING Do not stand over fire pit during ignition or operation due to high surface temperatures LIGHTING INSTR...

Page 14: ... consectetuer ajdsflkjasdlkjflaksdj flkjdflkjdflkasdjflkdjsflkajdsfl kjas d lkjf alksdj tc 90 C ta 60 C Top of Junction Box Equipment Ground Ground Brown Blue White Black Green Yellow Attach Ground Low Voltage High Voltage 30VDC Load Red Black Mounting holes in back of box Black Red Black Red 12 6 Junction box is 6 deep Polaity Sensistive 120VAC Power 12 gauge wire strain relief supplied by instal...

Page 15: ...ly and wires 1 FG PBA 3 LP Pilot Orifice not shown 1 FG PBO LP 4 30VDC Power Supply for single fire feature 10 feet from pools 1 GOE 30VDC 5 30VDC Power Supply in NEMA approved box for multi fire feature installs including pool spa installations 1 FG AWS PS 30V320 6 Heat Shield 1 FG HEATSHIELD 7 AWS Power Wire to Valve 1 10626 8 Key Valve Faceplate and Switch 1 78130 9 Weatherproof Rocker Switch 1...

Page 16: ...omeone connected 120VAC power directly to the gas valve the controller inside the valve box will be damaged It this happens a burned electrical smell might be present Connector Not Plugged In Correctly Check the 2 Pin connector from pilot to the gas valve Ensure it is plugged into place with the locking latch Pins Not Secure Check the pins inside the 2 pin connector ensure they are not loose If lo...

Page 17: ...oosen the thermopile from the pilot assembly and slide it out If it will not slide out because is it too tight then it will need to be replaced Debris Debris can get trapped inside the screen of the gas valve Over time rust and other debris can restrict the gas flow on the Outlet screen of the valve that can partially or sometimes even stop the flow Inspect the screen remove it and clean it then r...

Page 18: ...are Up effect Remove some of the fire glass media from the burner to see if this fixes the problem Gas Leak Natural Gas is lighter than air therefore when released into the atmosphere it rises If you have a Natural Gas fire feature and there is a gas leak the Natural Gas will rise to the top of the feature Once it encounters the flame a flare up will occur Propane is heavier than air so if there i...

Page 19: ...ackets to support fire pit when using paver blocks or other non combustible enclosures Emergency Stop Emergency shut off valve Model FG EMER STOP includes J Box and weatherproof cover ON OFF Switches Model FG WS OD On Off Wall Switch includes J Box and weather proof cover Model FG 1420 AOD Remote Control includes J Box and weather proof cover Timer Mechanical gas timer Model FG TIMER 2HR Includes ...

Page 20: ... FIVE 5 YEAR WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS FIVE 5 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS FIVE 5 YEAR WARRANTY SKYTECH MANUACF...

Page 21: ...OOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS SANCTUARY SERIES GFRC FIRE FEATURES THREE 3 YEAR WARRANTY GFRC STRUCTURE REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY WARRANTY COVERS MANUFACT...

Page 22: ...bor to repair the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty ...

Page 23: ...WS NOTES Manual changes often occur ensure to check the Firegear Outdoor website for any recent updates and warranty information FOR TECHNICAL SERVICE CALL Firegear Outdoors 17322 Gothard St Huntington Beach CA 92647 Web Site www firegearoutdoors com 800 966 8126 ...

Page 24: ...__________ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 Be prepared to send photo...