Firegear Outdoors All Weather Ignition System (AWS)
REV. D Page 4
SPECIFICATIONS
Table 1
Installation specifications * Used with Sanctuary 2 models only.
Model:
Natural Gas
Orifice
Size #
Model:
Propane Gas
Orifice
Size #
Btu’s
FPB-29RBSAWS-N
#16
FPB-29RBSAWS-P
#31
125,000 (36.63kW)
FPB-33RBSAWS-N
#5
FPB-33RBSAWS-P
#26
175,000 (51.28kW)
FPB-26DBSAWS-N
#16
FPB-26DBSAWS-P
#31
125,000 (36.63kW)
FPB-29DBSAWS-N
#16
FPB-29DBSAWS-P
#31
125,000 (36.63kW)
FPB-34DBSAWS-N
#5
FPB-34DBSAWS-P
#26
175,000 (51.28kW)
FPB-39DBSAWS-N
25/64” FPB-39DBSAWS-P
#12
250,000 (73.26kW)
FPB-44DBSAWS-N
25/64” FPB-44DBSAWS-P
#12
250,000 (73.26kW)
Table 2
Btu Specifications for Burner Spur by Firegear Outdoors
Pressure
NG
LP
Min. Inlet
3.5” WC (⅛ PSI) (0.87kPa)
8.0” WC (⅓ PSI) (1.99kPa)
Max. Inlet
14.0” WC (½ PSI) (3.48kPa)
14.0” WC (½ PSI) (3.48kPa)
Normal Inlet 7.0” WC (¼ PSI) (1.74 kPa)
11.0” WC (⅓ PSI) (2.73 kPa)
Table 3
Gas Pressures
Disclaimer:
Btu listings are based
on 7.0”WC for Natural Gas and
11.0”WC for Liquid Propane (LP)
at the burner orifice when using
Firegear Outdoors Burning Spurs.
If you use a burner other than a
Burning Spur, Btu’s will vary.
Note:
Flex line size and proper
gas pipe sizing will also affect
Btu’s. As a result your Btu’s may
vary slightly from Table 2
specifications.
Fig. 2
Clearance to Combustibles
(Not to be used in an enclosed space)
Model:
Natural Gas
Model:
Propane Gas
A
Depth
B
Min/Max
Opening or
Diameter
C
Inside/
Outside
Dim.
D
Ground
Level
E
Side
Wall
F
Combustible
Ceiling
G
Combustible
Floor
FPB-29RBSAWS-N FPB-29RBSAWS-P
2½”
30 ¼”- 31”
29”ID
18”
36”
120”
18”
FPB-33RBSAWS-N FPB-33RBSAWS-P
2½”
34 ¼ - 35”
33”ID
18”
36”
120”
18”
*FPB-26DBSAWS-N *FPB-26DBSAWS-P
1/16”
Max. 24”
26”OD
18”
36”
120”
18”
FPB-29DBSAWS-N FPB-29DBSAWS-P
1/16”
Max. 27”
29”OD
18”
36”
120”
18”
FPB-34DBSAWS-N FPB-34DBSAWS-P
1/16”
Max. 32”
34”OD
18”
36”
120”
18”
FPB-39DBSAWS-N FPB-39DBSAWS-P
1/16”
Max. 37”
39”OD
18”
36”
120”
18”
FPB-44DBSAWS-N FPB-44DBSAWS-P
1/16”
Max. 42”
44”OD
18”
36”
120”
18”
F
E
G
CL
24”
Max
Overhang
Fig. 1
Shows pan on top view and disc on bottom view.
A
B
C
⅞”
TYP. (usable flat lip)
*
*
D
Ground Level (Earth)
Valve
Box