background image

!

"#$%&!#&$'!()!*+&!,(-$'!+..%(+)/$&0!+)'!12$!.-3'#/1&!3,!/345#&1(3)!3,!&#/2!,#$%&0!/3)1+()!

/2$4(/+%&!6)37!13!12$!81+1$!3,!9+%(,3-)(+!13!/+#&$!/+)/$-0!5(-12!'$,$/1&!+)':3-!312$-!-$.-3'#/1(;$!

2+-4<!=2(&!7+-)()*!(&!(&&#$'!.#-&#+)1!13!9+%(,3-)(+!>$+%12!?!8+,$1@!93'$!8$/<ABACD<E

!

REV. 10-24-12  Page 2

Specifications

3

Preparation for Non-Conbustible Structure

4

     Hard Piping to Fire Pit

4

     Cross Ventilation Requirements

4

     High Elevation

4

Installation into an Approved Enclosure

5

    Requirements

5

    Installing Key Valve & Piezo Ignitor

5

   Typical Installation Drawings

6

    Installing Battery in Piezo Ignitor

7

    

Ignitor Alignment

7

    

Installation of Lava Rock/Media

7

Operation

8

    

Lighting Instructions

8

    Air Shutter Adjustment

8

Replacement Parts

9

Replacement Parts List

10

Fire Pit Maintenance/ Trouble Shooting

11

Optional Accessories/Conversion Kits

11-12

Warranty

13

TABLE OF CONTENTS

NOTE:

  This installation instruction covers both Match Throw and Manual Spark 

Igntition systems.  Not all sections will be applicable to your particular application.

Matchlight Fire Pits

Summary of Contents for FPB-1212MSI/N

Page 1: ...ross ventilation Failure to provide proper ventilation can void the warranty Match Throw Description Manual Spark FPB 19MT N 19 rd pan firestar FPB 19MSI N FPB 25MT N 25 rd pan firestar FPB 25MSI N FPB 1212MT N 12 x12 sq pan firestar FPB 1212MSI N FPB 1414MT N 14 x14 sq pan firestar FPB 1414MSI N FPB 2020MT N 20 x20 sq pan firestar FPB 2020MSI N FPB 2626MT N 26 x26 sq pan firestar FPB 2626MSI N FP...

Page 2: ...8 8 A3 B2392 254 8 C D438E 3F 38 58 897 4 4659 958 G377 H C I 4 F234 56673589 38 58 897 4 4659 4 92 54 5 95 6 J F 8FJ 95 2 C 03 2 1 02 2 03 2 01 902 2 0 7 90 A 21 1 6 2 1 0 9 2 61 6 10 7 A 6 1 2 B 1 1 7 03 K L D M K 1L 0 1 1 2 1 03 1 4 5 6 1 7 28 27 2 03 5292 20 032 1 03 1 66 2 9 61 6 1 2 0 02 A 7B 0 0A 0 1 02 A 1529 1 2 0 9 9 9 2 B 1 1 61 6 10 7 C 7 03 2 0 02 A 6 1 02 7 2 0 9 2 01 902 03 1 3 4 1 ...

Page 3: ...alve Piezo Ignitor 5 Typical Installation Drawings 6 Installing Battery in Piezo Ignitor 7 Ignitor Alignment 7 Installation of Lava Rock Media 7 Operation 8 Lighting Instructions 8 Air Shutter Adjustment 8 Replacement Parts 9 Replacement Parts List 10 Fire Pit Maintenance Trouble Shooting 11 Optional Accessories Conversion Kits 11 12 Warranty 13 TABLE OF CONTENTS NOTE This installation instruction...

Page 4: ... inches 3 23 cm for each pound of propane LP contained in the tank see example below Every opening must have minmum dimensions to allow entrance of a 1 2 3 2 mm diameter rod Ventilation openings in side walls must not connunicate directly with other enclosures of the fire pit The cyclinder valve must be easily accessible by hand Connections should be easy to leak test inside the enclosure A door o...

Page 5: ... 2 22 FPB 5050MT N 240 000 Btu s 0 18 NG LP Min Inlet 5 0 WC 11 0 WC Max Inlet 10 5 WC 13 0 WC Table 3 Gas Pressures Model A Pan Depth B Min Max Install Opening C Inside Pan D Ground Level FPB 19MT N Rd 2 625 19 25 21 5 19 8 FPB 25MT N Rd 2 625 25 25 27 5 25 8 FPB 1212MT N Sq 2 625 12 25 13 75 12 8 FPB 1414MT N Sq 2 625 14 25 15 75 14 8 FPB 2020MT N Sq 2 625 20 25 21 75 20 8 FPB 2626MT N Sq 2 625 ...

Page 6: ...flared brass fitting to the end of the black iron pipe Be sure to clean the pipe threads and use Teflon tape or pipe sealant 5 Connect the female flared flex connector from the Fire Pit to the male flared brass fitting secured to the black iron pipe Note Flare to flare connections do not require Teflon tape or pipe sealant IMPORTANT Installation of Natural or LP gas should be done by a qualified i...

Page 7: ...esired or non combustible logs may be added for a campfire look If logs are chosen do not place on decorative glass base use only Lava Rock as the base NOTE If using all glass media glass must be a minimum of 1 4 inch diameter or larger 10 Gas lines and fittings must be installed in to the non combustible structure All gas connections must be leak tested before installation of the fire pit Soapy w...

Page 8: ...ble Wall Material Key Valve Primary Gas Supply Key Valve Side View Det a i l Non Combustible Wall Material Non Combustible Wall Material Securing Tab Securing Tab Self Securing Junction Box Piezo Ignitor Mounting Plate Piezo Wires P i ezo Ignitor Side View Det a i l Fig 5 Typical installation NOTE Gas supply shut off and flex line to the key valve are not supplied Matchlight Fire Pits ...

Page 9: ...cover plate and secure with the plastic mounting nut Insert the positive end of 1 AAA battery into the ingitor module and carefully screw the red button cap to the ignitor module until snug Careful not to over tighten the cap Attach the extension wires PIEZO23WH 25WH to the 2 probe spark ignitor Careful not to overtighten the cap Test the ignitor by pushing and holding the red button to ensure the...

Page 10: ...CAUTION Ensure you have leak tested the fire pit before operating 1 Insert key into gas valve 2 Push and hold the red button on the manual Piezo ignitor and ensure sparking is occurring at the probes inside the fire pit 3 Rotate the key counter clockwise in gas valve to allow gas to flow 4 Gas should ignite within 10 seconds or less If fire pit does not light within 10 seconds turn key clockwise t...

Page 11: ...REV 10 24 12 Page REPLACEMENT PARTS 1 2 3 5 8 6 7 O N O F F Side View 9 10 11 12 13 14 17 Matchlight Fire Pits ...

Page 12: ... shown 1 ST3 100 1030 5 1 2 NPT Conduit Lock Nut 1 ST3 113 1027 6 7 8 Flat Washer Spacer 1 ST3 113 1026 7 3 8 Flex Gas Line 28 inch Length 1 T 100 9898 28 7 1 2 Flex Gas Line 46 inch Length 1 T 200 9898 46 8 Air Shutter Orifice NG 50 Used on 12 Fire Pits 1 FPB 12NGCK 8 Air Shutter Orifice NG 42 Used on 14 Fire Pits 1 FPB 14NGCK 8 Air Shutter Orifice NG 31 Used on 19 20 Fire Pits 1 FPB 19NGCK 8 Air...

Page 13: ...iture 6 Over time stainless steel parts discolor when heated usually a golden or brown hue This discoloration is normal and does not affect the performance of the appliance REV 10 24 12 Page 12 TROUBLE SHOOTING Sympton Remedy Piezo won t spark 1 Be sure battery is installed properly 2 Check battery voltage Min 1 2 VDC needed 3 Check ignitor gap at probes inside fire pit Gap should be at 1 8 4 Doub...

Page 14: ... NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFER ENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT FOR TECHNICAL SERVICE CALL firegear LLC PO Box 871250 Canton MI 48187 888 220 4333 Ext 3 Fax 888 431 0585 WEB SITE www firegearusa com REV 10 24 12 Page 13 CONVERSION KITS OPTIONAL ACCESSORIES The following accessories...

Page 15: ...riod Travel diagnostic cost service labor to repair the defect and freight charges on warranty parts to and from the factory will be responsibility of the owner Fire Gear LLC will not be responsible for labor charges and or damage incurred in installation repair and replace ment or for incidental or consequential damages This Limited Warranty does not cover any failures or operating difficulties d...

Reviews: