background image

REV. B          Page 3

Burning Spur Kit

Specifications

4

Preparation for Non-Combustible Structure

5

     Hard Piping to Fire Pit

5

     High Elevation

5

     Cross Ventilation Requirements

5

     Pipe Sizing Chart

6

Installation into an Approved Enclosure

7

    Burning Spur Information

7

    Burning Spur Assembly

8

    Installing Key Valve 

8

    Typical Installation Drawings

9

Operation

10

    

Lighting Instructions

10

Replacement Parts

11

Replacement Parts List

12

Burning Spur Contents

13

Converting to Liquid Propane (LP) Gas

14

Fire Pit Maintenance/ Trouble Shooting

15

Optional Accessories

16

TABLE OF CONTENTS

All media (i.e. lava rock, lava stones, lava boulders and fire glass) has the potential of 

thermal spalling.  This is a process that may occur when media is wet and moisture gets 

trapped inside of the material due to rapid temperature differences.  When this happens 

the media has the potential to crack or “pop” outside the fire feature.

WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE

The use of a cover can lessen the impact of thermal spalling; however, heavy rains, high 

humidity and the presence of moisture may still cause the media to pop.

ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE 

Extra caution should be taken when lighting a fire feature when heavy rains, high humidity 

and moisture are present.  Light the fire feature; leave the area allowing any moisture in 

the media to dissipate.  We strongly recommend that during this drying out time that you 

monitor the fire feature from a distance.  This drying out period should be no less than 30 

minutes.  Continue monitoring the flame from distance to ensure that all popping has 

ceased before fully enjoying the fire. 

CAUTION

CALIFORNIA PROPOSITION 65 

WARNING

This product can expose you to Chromium, which is 

known to the state of California to cause cancer 

and birth defects or other reproductive harm.

(For more information, go to www.p65warnings.ca.gov)

Summary of Contents for DBS-12

Page 1: ...inch Spur Burner Kit 50 000 Btu s DBS 16 16 inch Spur Burner DBS 16K 16 inch Spur Burner Kit 75 000 Btu s DBS 22 22 inch Spur Burner DBS 22K 22 inch Spur Burner Kit 100 000 Btu s DBS 31 31 inch Spur...

Page 2: ...ave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation adjustment alteration service or maintenance can cause i...

Page 3: ...as the potential to crack or pop outside the fire feature WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rain...

Page 4: ...Burner models above are not provided with pans for installation We suggest you provide an appropriate non combustible burner pan to install the Burning Spur Burner pans sizes listed in Table 1 are su...

Page 5: ...all Liquid Propane LP tanks outside the enclosure 6 To prevent performance problems with LP gas fire pits do not use a LP tank less than 100lbs capacity IMPORTANT Installation of Natural or LP gas sh...

Page 6: ...the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure Th...

Page 7: ...to keep the enclosure dry 9 These products are designed for outdoor use only Not approved for any indoor use or any enclosed space 10 This fire pit is designed to have Firegear Outdoors lava rock or g...

Page 8: ...mended to use the key valve assembly provided in the Burning Spur kit Otherwise you will need to provide a key valve for the installation GAS FLOW Burner Pan OAS U3 8D S BURNING SPUR ASSEMBLY Fig 5 Na...

Page 9: ...hut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple not supplied can be used as a spacer between the manual valve and the valve flange to add additional support to hold the ma...

Page 10: ...use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or Propane gas line WARNING 1 This appliance is hot when...

Page 11: ...REV B Page 11 Burning Spur Kit REPLACEMENT PARTS 1 2 5 4 Drawings not to scale 8 9 3 O N O F F 6 7...

Page 12: ...ecific orifice sizes model numbers 3 OAS Orifice air shutter for LP Gas Fire Pits 1 Refer to page 4 of manual for specific orifice sizes model numbers 4 1 2 Flex Gas Line 46 inch Length used with all...

Page 13: ...B Spur OAS U3 8D S Burning Spur Only Contents Models DBS 12 DBS 16 DBS 22 DBS 31 DBS 36 GAS FLOW 12 inch Key T200 9898 46 Key Valve U1 8D S B Spur Flange OAS U3 8D S Burning Spur Kit Contents Models...

Page 14: ...OAS LP26 DBS 31 DBS 31K OAS LPK19 S499 8 113 SS4 D5 U3 8D S 225 000 65 94kW OAS LP19 DBS 36 DBS 36K When converting Burners to LP gas the main burner orifice must be kept a minimum of 6 inches away fr...

Page 15: ...the fire pit when not in use be sure to remove it before operation to prevent a severe safety hazard 5 Over time stainless steel parts can discolor when heated usually a golden or brown hue This disc...

Page 16: ...lass Reflective Glass Sold in 5lb bags in various colors See your Firegear dealer for various options Paver System Model PAVER CP MT Paver bracket key valve parts for match throw system Model PAVER CP...

Page 17: ...NTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONST...

Page 18: ...A BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTEC...

Page 19: ...defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Fire...

Page 20: ...or consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale i...

Page 21: ...REV B Page 21 Burning Spur Kit Notes...

Page 22: ...rial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of...

Reviews: