Firefox OGF - 2.7/ZC Installation & Operating Instructions Manual Download Page 4

OGF - ZC Series

OPEN GAS FIREBOX SPECIFICATIONS

FRONT

TOP

RIGHT HAND SIDE

B

FLUE

SPIGOT

FLUE

SPIGOT

FAN

FAN

FAN 

SWITCH

POWER

SUPPLY

POWER

SUPPLY

GAS PIPE

INLET

GAS PIPE

INLET

FLUE

SPIGOT

50

130

140

75

75

For installation and

commisioning procedure of

the Gas Firegrate/Burner

‘GFG’ refer to seperate

instructions entitled; 

INSTALLATION & OPERATING

INSTRUCTIONS ‘GFG’ Series

FIREGRATES.

FIREBOX 

MODEL

FIREBOX DIMENSIONS

A       B       C        D       E      F

720  655  400  160  680  630 

780  690  420  155  740  665

900  725  435  155  860 700

}

}

}

FLUE

INNER/OUTER

178

(7”)

229

(9”)

203

(8”)

254

(10”)

229

(9”)

280

(11”)

}
}

}

APPROPRIATE GAS 

FIREGRATE ‘GFG’

GFG 2.7

GAS INPUT

NG        LP

36 - 35 Mj Hr

41 - 40 Mj Hr 

52 - 50 Mj Hr 

GFG 3.0

GFG 3.5

OGF - 27/ZC

OGF - 30/ZC

OGF - 35/ZC

Summary of Contents for OGF - 2.7/ZC

Page 1: ...egulations AGA 601 code for installation of gas burning appliances electrical wiring regulations and any other statutory requirement The guidelines here in have been tested and approved to AS 4558 AG 108 AGAApproval No 6386 HOT AIR OUTLETS FLUE SPIGOT FIREFOX OGF ZC FIREBOX CONTROL COVER PANEL GAS INLET COLD AIR INTAKE FAN SWITCH ELECTRIC CORD GAS FIREGRATE GFG For the appropriate Gas Firegrate GF...

Page 2: ... to not obstruct the fitting of a decorative surround i e mantelpiece 4 Construct timber framing as required to suit the selected Firefox firebox See example detail Maintain 25mm clearance to the sides and back of the firebox and 50mm clearance from the top from combustible materials Secure firebox into position with metal strapping Plasterboard can be zero clearance to the perimeter face flange o...

Page 3: ...ED SURROUND CHECK SPEC SELECTION FRAME DEPTH 300 MIN INNER FLUE STAINLESS SEE BELOW 130 R L 25 NOTE DO NOT LOCATE ANY EXTRACTION AIR DEVICE WHICH MAY CAUSE A NEGATIVE AIR PRESSURE IN THE ROOM WHERE THE GAS FIRE IS LOCATED VENTILATION OF 400cm2 IS REQUIRED INTO THE ROOM WHERE THE GAS FIRE IS LOCATED e g ROOF CEILING SPACE OUTSIDE WALL CAVITY OR SUB FLR AREA PLUMBING ELECTRICAL MUST BE CARRIED OUT B...

Page 4: ...g procedure of the Gas Firegrate Burner GFG refer to seperate instructions entitled INSTALLATION OPERATING INSTRUCTIONS GFG Series FIREGRATES FIREBOX MODEL FIREBOX DIMENSIONS A B C D E F 720 655 400 160 680 630 780 690 420 155 740 665 900 725 435 155 860 700 FLUE INNER OUTER 178 7 229 9 203 8 254 10 229 9 280 11 APPROPRIATE GAS FIREGRATE GFG GFG 2 7 GAS INPUT NG LP 36 35 Mj Hr 41 40 Mj Hr 52 50 Mj...

Page 5: ...her than 50mm max forward of the face of the firebox Mantle shelves must be 300mm min clear above the top edge of the firebox and must not project more than 250mm max forward of the face of the firebox A non combustible floor protector forehearth at the base directly in front of the firebox opening must be a minimum of 6mm thick project a minimum 300mm forward and 200mm on each side of the firebox...

Page 6: ... area where the FIREFOX is located The fan control switch is located on the lower left hand front of the unit The fan can remain OFF whilist the gas firegate is in operation To boost heat output simply select one of the two fan speeds avaliable i e LOW or HIGH Your FIREFOX gas unit is relatively maintenance free However we recommend that you have the appliance installation checked once a year to e...

Reviews: