Tap to Enable/Disable AGS (as described on page 5).
Trigger Options
–
Automatically start the generator using specified voltage settings
(Low Volts) or when A/C or Heat Pump starts (HVAC). Select one or both triggers.
If no triggers are selected, AGS will not run. Disable HVAC Load while connected to
shore power to keep the generator from starting.
Generator Hours Reset
–
Press and hold the accumulated hours tally for seven seconds to enter the
hours reset screen. This process should only be done after replacing or servicing the generator or to
sync the hours on the screen with the hour meter on the generator.
Start at Volts - The generator will start when the voltage drops to this set point
depending on “Time a Volts” setting below.
(Range 10.5v
–
12.5v)
Time at Start Volts - The generator will start when the voltage drops to the Start at
Voltage for this specific amount of time. (Range 5 seconds
–
1 minute)
5 seconds
–
1
minute)
Stop at Volts - The generator will shut off when the voltage reaches this set point
depending on “Time at Stop Volts” setting below.
(Range 13.2v
–
14.5v)
Time at Stop Volts - The amount of time required for the volt
age to remain at “Stop at
Volts” level before the generator shuts off.
(Range 5min
–
120 min)
Minimum Gen Run Time - Use the +/- buttons to set the minimum amount of time that
your generator will run once it has started. (Range 10min
–
30 min)
0min
–
30min)
Maximum Gen Run Time - Use the +/- buttons to set the maximum amount of time that
your generator will run once it has started. (Range 120min
–
300min)
(Range 120min
–
240min)
–
30min)
Gen Start Retries - Use the +/- buttons to set the number of tries that your generator
will retry to start. (Range 1-5 retries)
–
30min)
Auto Gen Start Settings