![Firefly 87510011 Manual Download Page 7](http://html1.mh-extra.com/html/firefly/87510011/87510011_manual_2291514007.webp)
7
This screen will summarize the complete electrical system (DC, AC, and Generator).
This system uses an AC Power Monitor Module to monitor Voltage and Amperage for the purposes of
EMS (Energy Management System). EMS will ensure that power is available before allowing certain
systems to run. If power is not available, it will not allow particular systems to run (shed the load).
Note
–
EMS HAS BEEN DISABLED ON 50 Amp Shore and Generator power, so loads will not shed while
the system is under these two conditions (barring the initial load shed when the generator is first
starting up or when the generator is transitioning).
EMS will shed in the following order:
-Center A/C
-Front A/C
-Rear A/C
Power Source Select
–
50-amp shore power will display automatically if connected to a 50-amp line. Tap
to select 30, 20 or 15 amp if your coach is connected to a 30-amp line.
Electrical
1
1
A/C Power Summary
Tap to enable AGS.
Tap to navigate to AGS Settings.